Prysmian Cables & Systems Ltd Visit Website
Prysmian Cables & Systems Ltd
Chickenhall Lane,
Eastleigh,
SO50 6YU,
Hampshire,
United Kingdom
Telephone:
087051 33143
Products (Filtered of )
-
BS EN 50525-3-41:2011
View Certificate PDF 620KBTable Number:
Table 4.1Schedule:
017/004/317Approved Range:
Single core non-sheathed cables with LSHF crosslinked insulationDetail:
N/A -
BS EN 50525-2-31:2011
View Certificate PDF 620KBTable Number:
Table 4.1Schedule:
017/004/318Approved Range:
Single core non-sheathed cables with thermoplastic PVC insulationDetail:
N/A -
BS 7889:2012
View Certificate PDF 545KBTable Number:
Table 2Schedule:
017/004/320Approved Range:
Non-armoured power cables with PVC sheathingDetail:
N/A -
BS 7629-1:1997 Incorporating Amendment Nos. 1 and 2
View Certificate PDF 545KBTable Number:
Table 2Schedule:
017/004/321Approved Range:
Fire resistant screened cables -
BS 7629-1:1997 Incorporating Amendment Nos. 1 and 2
View Certificate PDF 546KBTable Number:
Table 2Schedule:
017/004/323Approved Range:
Fire resistant screened cablesDetail:
Core colour sequence - 2 plus uninsulated CPC: red, black, Three-core plus uninsulated CPC: red, yellow, blue, Four-core plus uninsulated CPC: red, yellow, blue, black. -
BS 7629-1:2015
View Certificate PDF 545KBTable Number:
Table 2Schedule:
017/004/324Approved Range:
Fire resistant screened cablesDetail:
STANDARD 60. Additionally tested to BS 6387:2013 Category CWZ. -
BS 7629-1:2015
View Certificate PDF 545KBTable Number:
Table 2Schedule:
017/004/325Approved Range:
Fire resistant screened cablesDetail:
ENHANCED 120. Additionally tested to BS 6387:2013 Category CWZ. -
BS 7629-1:2015
View Certificate PDF 562KBTable Number:
Table 2Schedule:
017/004/326Approved Range:
Fire resistant screened cablesDetail:
ENHANCED 120. Additionally tested to BS 6387:2013 Category CWZ. -
BS 7629-1:2015
View Certificate PDF 618KBTable Number:
Table 2, Table 3Schedule:
017/004/327Approved Range:
Fire resistant screened cablesDetail:
STANDARD 30. Additionally tested to BS 6387:2013 Category CWZ. -
BS 7846:2015
View Certificate PDF 546KBTable Number:
Table 4, Table 5, Table 7Schedule:
017/004/330Approved Range:
Armoured fire resistant power cablesDetail:
Resistance to fire - Category F120. This approval is based on the use of 1.25mm armour wire for the following cables: Table 4, 2, 4, 6 & 10sqmm, Table 5, three-core, 4 & 6 sqmm and Table 6, four-core, 4sqmm, Table 7, five-core, 4sqmm. -
BS 8436:2011
View Certificate PDF 579KBTable Number:
Table 1Schedule:
017/004/331Approved Range:
Screened cablesDetail:
N/A -
BS 5467:2016 Incorporating Corrigendum No. 1
View Certificate PDF 578KBTable Number:
Table 5, Table 9, Table 6, Table 8Schedule:
017/004/337Approved Range:
Armoured power cables with PVC sheathingDetail:
N/A -
BS 7846:2015
View Certificate PDF 545KBTable Number:
Table 4, Table 8, Table 5, Table 7Schedule:
017/004/340Approved Range:
Armoured fire resistant power cablesDetail:
Resistance to fire - Category F2. -
BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2
View Certificate PDF 578KBTable Number:
Table 5, Table 9, Table 6, Table 8Schedule:
017/004/341Approved Range:
Armoured power cables with LSHF sheathingDetail:
N/A -
BS 7629-1:2015
View Certificate PDF 545KBTable Number:
Table 2Schedule:
017/004/342Approved Range:
Fire resistant screened cablesDetail:
Standard 60 -
BS 8592:2016
View Certificate PDF 577KBTable Number:
Table 2Schedule:
017/004/343Approved Range:
Single core fire resistant cablesDetail:
These cables conform to BS 8592, and by reference, conform to the appropriate requirements of BS EN 60228, BS EN 60332-1-2, BS EN61034-2, BS EN 60754-1 and IEC 60331-3. Additionally tested to BS 8434-2:2003+A2:2009 and BS EN 50200:2015 PH120 (tests conducted in steel conduit). These cables have a rated voltage of 450/750V
Quality (ISO 9001)
-
CS1-084/001.2
View Certificate PDF 171KBScope:
Corporate Management and Administrative functions for the UK Business and Factories. The design, development, manufacture and supply of: Energy cables for Special, Industrial, Fire Performance Applications up to 1.0 kV using PVC, Polymeric & Elastomeric Compounds. The design, development and manufacture of: Low Smoke and Special Cable Compounds
BASEC PCR
-
PCR-084/001.2
View Certificate PDF 159KBScope:
The design, development, manufacture and supply of: Energy cables for Special, Industrial and Fire Performance Applications up to 1.kV using PVC, Polymeric & Elastomeric Compounds. The design, development and manufacture of: Low smoke and Special Cable Compounds.
CPR Classification Reports
-
BS EN 50525-3-41:2011, Single-core, 1.5 mm² and 6.0 mm²
Report No. W4CPRT130
Issue Date: 4th January 2024
-
BS 6622 3x150sqmm AL 11kV, Product Code: 20398475/VHAD3G15CABARD
Report No. T1CPRT130
Issue Date: 21st February 2023
-
Family 14 - BS EN 50525-3-41 H07Z-R Single Core
Report No. L3CPRT130
Issue Date: 30th June 2017
-
Family 23 - BS 7835 11kV 3 Core Conductor
Report No. L1CPRT130-2
Issue Date: 22nd May 2017
-
Family 14 - BS EN 50525-3-41 H07Z-R Single Core
Report No. K1CPRT063-1
Issue Date: 25th April 2017
-
Family 18 - BS 6724 Large Circular Conductor
Report No. K1CPRT063-2
Issue Date: 25th April 2017
Certificates of Constancy of Performance
-
BS EN 50525-3-41 H07Z-R Single Core
Certificate No. 2661-CPR-0006
Issue Date: 29th June 2017
-
BS 6724 Large Circular Conductor
Certificate No. 2661-CPR-0007
Issue Date: 15th May 2017
-
BS 6724 Multicore Shaped Conductor
Certificate No. 2661-CPR-0009
Issue Date: 15th May 2017