Dongguan Keystone Electric Wire & Cable Co., Ltd Visit Website

Origin Mark:
<KEYSTONE>

Dongguan Keystone Electric Wire & Cable Co., Ltd
Ye Sha Management District,
Shatian,
Dongguan City,
523998,
Guangdong,
China

Telephone:
00867 698886723

Products (Filtered of )

Filters (1) Edit filter

  • BS 6231:2006 Incorporating Corrigendum No.1
    View Certificate PDF 772KB

    Table Number:
    Table 2

    Schedule:
    075/001/180

    Approved Range:
    Single core non-sheathed cables with thermoplastic PVC insulation

    Detail:
    The above cables conform to BS 6231 and, by reference, conform to the appropriate requirements of BS EN 60228. These cables have a rated voltage of 600/1000 V.

  • BS 6004:2000 Incorporating Amendment Nos. 1 and 2
    View Certificate PDF 796KB

    Table Number:
    Table 4a

    Schedule:
    075/001/186

    Approved Range:
    PVC insulated and sheathed cables

    Detail:
    These cables conform to BS 6004 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 7919:2001 Incorporating Amendment Nos. 1, 2 and
    View Certificate PDF 754KB

    Table Number:
    Table 40

    Schedule:
    075/001/188

    Approved Range:
    Industrial flexible cables

    Detail:
    These cables conform to BS 7919 and, by reference, conform to the appropriate requirements of BS EN 60228. These cables have a rated voltage of 300/500 V.

  • IEC 60502-1 Edition 2.1:2009
    View Certificate PDF 781KB

    Table Number:
    Table N/A

    Schedule:
    075/001/193

    Approved Range:
    Low voltage power cables up to 1kV

    Detail:
    These cables conform to IEC 60502-1 and, by reference, conform to the appropriate requirements of: IEC 60228, IEC 60332-3-24 Cat C, IEC 60332-1-2, IEC 61034-2, IEC 60684-2 and IEC 60754 specifications.                       These cables have a rated voltage of 600/1000 V.

  • IEC 60227-3:1993 Incorporating Amendment No.1 1997
    View Certificate PDF 706KB

    Table Number:
    Table 9

    Schedule:
    075/001/194

    Approved Range:
    Single core PVC insulated wires

    Detail:
    These cables conform to IEC 60227-3 and, by reference, conform to the appropriate requirements of IEC 60228.                  These cables have a rated voltage of 300/500 V.

  • BS 6622:2007 Incorporating Corrigenda Nos. 1 and 2
    View Certificate PDF 639KB

    Table Number:
    Table N/A

    Schedule:
    075/001/198

    Approved Range:
    Medium voltage power cables up to 33kV with PVC/MDPE sheathing

    Detail:
    Refer to certificate for details.

  • BS 7835:2007 Incorporating Corrigendum No.1
    View Certificate PDF 639KB

    Table Number:
    Table N/A

    Schedule:
    075/001/214

    Approved Range:
    Medium voltage power cables up to 33kV with LSHF sheathing

    Detail:
    Refer to certificate for details.

  • BS 7211:2012
    View Certificate PDF 758KB

    Table Number:
    Table 4

    Schedule:
    075/001/219

    Approved Range:
    LSHF insulated and sheathed cables

    Detail:
    These cables conform to BS 7211 and, by reference, conform to the appropriate requirements of BS EN 60228, BS EN 60332-1-2, BS EN 60332-3-24, BS EN 61034-2 and BS EN 60754-1 specifications.  These cables have a rated voltage of 450/750 V.

  • BS 7211:2012
    View Certificate PDF 683KB

    Table Number:
    Table 5

    Schedule:
    075/001/220

    Approved Range:
    LSHF insulated and sheathed cables

    Detail:
    These cables conform to BS 7211 and, by reference, conform to the appropriate requirements of BS EN 60228, BS EN 60332-1-2, BS EN 61034-2 and BS EN 60754-1 specifications. These cables have a rated voltage of 300/500 V.

  • BS 7846:2015
    View Certificate PDF 602KB

    Table Number:
    Table 4, Table 6, Table 5

    Schedule:
    075/001/221

    Approved Range:
    Armoured fire resistant power cables

    Detail:
    Refer to certificate for full details

  • BS 7846:2015
    View Certificate PDF 607KB

    Table Number:
    Table 4, Table 6, Table 5

    Schedule:
    075/001/224

    Approved Range:
    Armoured fire resistant power cables

    Detail:
    Refer to certificate for details

  • IEC 60502-2:2014
    View Certificate PDF 670KB

    Table Number:
    Table N/A

    Schedule:
    075/001/225

    Approved Range:
    Medium voltage power cables up to 33kV

    Detail:
    Refer to certificate for details.

  • IEC 60502-2:2014
    View Certificate PDF 686KB

    Table Number:
    Table N/A

    Schedule:
    075/001/226

    Approved Range:
    Medium voltage power cables up to 33kV

    Detail:
    Refer to certificate for details.

  • BS 8592:2016
    View Certificate PDF 641KB

    Table Number:
    Table 2

    Schedule:
    075/001/227

    Approved Range:
    Single core fire resistant cables

    Detail:
    These cables conform to BS 8592, and by reference, conform to the appropriate requirements of: BS EN 60228, BS EN 60332-1-2, BS EN 61034-2, BS EN 60754-1 and IEC 60331-2. Additionally tested to BS 6387:2013 CWZ, BS EN 50200:2015 PH120 (120 mins), BS EN 50200:2015 Annex E, BS 8434-2:2003+A2:2009; IEC 60331-21:1999 (all preceding tests conducted in steel conduit); BS EN 60754-2:2014.               These cables have a rated voltage of 450/750 V.

  • BS 7846:2015
    View Certificate PDF 647KB

    Table Number:
    Table 8

    Schedule:
    075/001/228

    Approved Range:
    Armoured fire resistant power cables

    Detail:
    Refer to certificate for details

  • BS 5467:2016 Incorporating Corrigendum No. 1
    View Certificate PDF 555KB

    Table Number:
    Table 5, Table 7, Table 6

    Schedule:
    075/001/231

    Approved Range:
    Armoured power cables with PVC sheathing

    Detail:
    Ranges 1.5sqmm to 120sqmm are circular stranded conductors and ranges 25sqmm to 400sqmm are shaped stranded conductors. Any core colour sequence meeting regulatory requirements permitted.  These cables conform to BS 5467 and, by reference, conform to appropriate requirements of BS EN 60228. These cables have a rated voltage of 600/1000 V.

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2
    View Certificate PDF 607KB

    Table Number:
    Table 5, Table 7, Table 6

    Schedule:
    075/001/232

    Approved Range:
    Armoured power cables with LSHF sheathing

    Detail:
    Ranges 1.5sqmm to 120sqmm are circular stranded conductors and ranges 25sqmm to 400sqmm are shaped stranded conductors.  Any core colour sequence meeting regulatory requirements permitted. These cables conform to BS 6724 and, by reference, conform to appropriate requirements of BS EN 60228, BS EN 60332-1-2, BS EN 60332-3-24, BS EN 61034-2 and BS EN 60754-1.                             These cables have a rated voltage of 600/1000 V.

  • BS EN 50525-2-31:2011
    View Certificate PDF 634KB

    Table Number:
    Table 4.1, Table 4.3, Table 4.4

    Schedule:
    075/001/233

    Approved Range:
    Single core non-sheathed cables with thermoplastic PVC insulation

    Detail:
    These cables conform to BS EN 50525-2-31 and, by reference, conform to the appropriate requirements of BS EN 60228. These cables have a rated voltage of 450/750 V for Clause 4.1/Table B.1 and 300/500 V for Clause 4.3/Table B.3 & Clause 4.4/Table B.4.

  • BS 6004:2012
    View Certificate PDF 721KB

    Table Number:
    Table 3, Table 4, Table 5

    Schedule:
    075/001/234

    Approved Range:
    PVC insulated and sheathed cables

    Detail:
    These cables conform to BS 6004 and, by reference, conform to the appropriate requirements of BS EN 60228.  These cables have a rated voltage of 300/500 V.

  • BS 6500:2000 Incorporating Amendment Nos. 1, 2 and
    View Certificate PDF 601KB

    Table Number:
    Table 26, Table 27

    Schedule:
    075/001/235

    Approved Range:
    Flexible cables with thermoplastic PVC insulation

    Detail:
    These cables conform to BS 6500 and, by reference, conform to the appropriate requirements of BS EN 60228. These cables have rated voltages of 300/300 V for Table 26 and 300/500 V for Table 27.

  • BS EN 50525-2-11:2011
    View Certificate PDF 600KB

    Table Number:
    Table 4.1, Table 4.2

    Schedule:
    075/001/236

    Approved Range:
    Flexible cables with thermoplastic PVC insulation

    Detail:
    These cables conform to BS EN 50525-2-11 and, by reference, conform to the appropriate requirements of BS EN 60228. These cables have a rated voltage of 300/300 V for Clause 4.1/Table B.1 and 300/500V for Clause 4.2/Table B.2.

  • BS 7211:1998 Incorporating Amendments Nos. 1 and 2
    View Certificate PDF 651KB

    Table Number:
    Table 3a, Table 3b, Table 4b

    Schedule:
    075/001/237

    Approved Range:
    LSHF insulated and sheathed cables

    Detail:
    These cables conform to BS 7211 and, by reference, conform to the appropriate requirements of: BS EN 60228, BS EN 60332-1-2, BS EN 61034-2 and BS EN 60754-2 specifications. These cables have a rated voltages of 450/750 V for Table 3a & 3b and 300/500 V for Table 4b.

  • BS EN 50525-3-41:2011
    View Certificate PDF 608KB

    Table Number:
    Table 4.1, Table 4.2, Table 4.3, Table 4.4

    Schedule:
    075/001/238

    Approved Range:
    Single core non-sheathed cables with LSHF crosslinked insulation

    Detail:
    These cables conform to BS EN 50525-3-41 and, by reference, conform to the appropriate requirements of: BS EN 60228, BS EN 60332-1-2, BS EN 61034-2, BS EN 60754-1, BS EN 60754-2 and BS EN 60684-2 specifications. These cables have rated voltages of 450/750 V for Clause 4.1/Table B.1 & Clause 4.2/Table B.2 and 300/500 V for Clause 4.3/Table B.3 & Clause 4.4/Table B.4.

  • BS 7889:1997 Incorporating Amendment Nos. 1, 2 and
    View Certificate PDF 554KB

    Table Number:
    Table 4

    Schedule:
    075/001/239

    Approved Range:
    Non-armoured power cables with PVC sheathing

    Detail:
    These cables conform to BS 7889 and, by reference, conform to the appropriate requirements of BS EN 60228. 960 sqmm nominal cross-sectional area of conductor which shall compromise of four 'solid' sector shaped sections laid up together. These cables have a rated voltage of 600/1000 V.

  • BS 7889:2012
    View Certificate PDF 551KB

    Table Number:
    Table 2, Table 3, Table 4, Table 5

    Schedule:
    075/001/240

    Approved Range:
    Non-armoured power cables with PVC sheathing

    Detail:
    Any core colour sequence meeting regulatory requirements. These cables conform to BS 7889 and, by reference, conform to the appropriate requirements of BS EN 60228. These cables have a rated voltage of 600/1000 V.

Quality (ISO 9001)

  • CS1-129
    View Certificate PDF 176KB

    Scope:
    The Design, Development, Manufacture and Supply of the following cable types: Electric Wires, Energy Cables, Control Cables, Fire Resistant Cables and Branch Cables rated up to 1.2 kV, Medium Voltage Cables with Thermoset Insulation up to 36 kV. Telecommunications Cables up to 100 pairs, Category 5 Cables to 5E and frequency up to 150 MHz Materials used: Copper, Aluminium, GSW, PE, PVC, XLPE, Low Smoke Halogen Free and Elastomeric Compounds . The Development and Manufacture of PVC Compounds.

BASEC PCR

  • PCR-129
    View Certificate PDF 160KB

    Scope:
    The Design, Development, Manufacture and Supply of the following cable types: Electric Wires, Energy Cables, Control Cables and Fire Resistant Cables rated up to 1.2 kV & Medium Voltage Cables with Thermoset Insulation up to 36 kV. Materials used: Copper, Aluminium, GSW, PE, PVC, XLPE, Low Smoke Halogen Free and Elastomeric Compounds.