Dongguan Keystone Electric Wire & Cable Co., Ltd Visit Website
Dongguan Keystone Electric Wire & Cable Co., Ltd
Ye Sha Management District,
Shatian,
Dongguan City,
523998,
Guangdong,
China
Telephone:
00867 6988867234
Products (Filtered of )
-
BS 6231:2006 Incorporating Corrigendum No.1
View Certificate PDF 572KBTable Number:
Table 2Schedule:
075/001/180Approved Range:
Single core non-sheathed cables with thermoplastic PVC insulationDetail:
The above cables conform to BS 6231 and, by reference, conform to the appropriate requirements of BS EN 60228. These cables have a rated voltage of 600/1000 V. -
IEC 60502-1 Edition 2.1:2009
View Certificate PDF 584KBTable Number:
Table N/ASchedule:
075/001/193Approved Range:
Low voltage power cables up to 1kVDetail:
These cables conform to IEC 60502-1 and, by reference, conform to the appropriate requirements of: IEC 60228, IEC 60332-3-24 Cat C, IEC 60332-1-2, IEC 61034-2, IEC 60684-2 and IEC 60754 specifications. These cables have a rated voltage of 600/1000 V. -
IEC 60227-3:1993 Incorporating Amendment No.1 1997
View Certificate PDF 573KBTable Number:
Table 9Schedule:
075/001/194Approved Range:
Single core PVC insulated wiresDetail:
These cables conform to IEC 60227-3 and, by reference, conform to the appropriate requirements of IEC 60228. These cables have a rated voltage of 300/500 V. -
BS 6622:2007 Incorporating Corrigenda Nos. 1 and 2
View Certificate PDF 798KBTable Number:
Table N/ASchedule:
075/001/198Approved Range:
Medium voltage power cables up to 33kV with PVC/MDPE sheathingDetail:
Circular stranded plain copper or aluminium conductors (class 2), extruded cross-linkable semi-conducting conductor screen, extruded cross-linkable polyethylene (XLPE GP 8) insulation, extruded cross-linkable semi-conducting bonded or strippable insulation screen, copper tape and/or copper wire screened, extruded polyvinyl chloride (PVC) separation sheath, aluminium wire armour for single core cables and galvanized steel wire armour for three core cables, extruded polyvinyl chloride (PVC Type 9) oversheath. The cables' design, materials, and testing conform to BS 6622 and BS EN 60228. The cables have a rated voltage ? 3.8/6.6 (7.2)kV; 6.35/11 (12) kV; 8.7/15 (17.5) kV; 12.7/22 (24)kV and 19/33 (36)kV. -
BS 7835:2007 Incorporating Corrigendum No.1
View Certificate PDF 759KBTable Number:
Table N/ASchedule:
075/001/214Approved Range:
Medium voltage power cables up to 33kV with LSHF sheathingDetail:
Circular stranded plain copper or aluminium conductors (class 2), extruded cross-linkable semi-conducting conductor screen, extruded cross-linkable polyethylene (XLPE GP 8) insulation, extruded cross-linkable semi-conducting bonded or strippable insulation screen, copper tape and/or copper wire screened, extruded low smoke non-halogen (LSNH) separation sheath, aluminium wire armour for single core cables and galvanized steel wire armour for three core cables, extruded low smoke non-halogen (LSNH LTS 1) oversheath. The cables' design, materials, and testing conform to BS 7835, BS EN 60228, BS EN 60332-1-2, BS EN 60332-3-24, BS EN 61034-2, and BS EN 60754-1. The cables have a rated voltage ? 3.8/6.6 (7.2)kV; 6.35/11 (12) kV; 8.7/15 (17.5) kV; 12.7/22 (24)kV and 19/33 (36)kV. -
BS 7211:2012
View Certificate PDF 579KBTable Number:
Table 4Schedule:
075/001/219Approved Range:
LSHF insulated and sheathed cablesDetail:
These cables conform to BS 7211 and, by reference, conform to the appropriate requirements of BS EN 60228, BS EN 60332-1-2, BS EN 60332-3-24, BS EN 61034-2 and BS EN 60754-1 specifications. These cables have a rated voltage of 450/750 V. -
BS 7211:2012
View Certificate PDF 580KBTable Number:
Table 5Schedule:
075/001/220Approved Range:
LSHF insulated and sheathed cablesDetail:
These cables conform to BS 7211 and, by reference, conform to the appropriate requirements of BS EN 60228, BS EN 60332-1-2, BS EN 61034-2 and BS EN 60754-1 specifications. These cables have a rated voltage of 300/500 V. -
BS 7846:2015
View Certificate PDF 950KBTable Number:
Table 4, Table 6, Table 5Schedule:
075/001/221Approved Range:
Armoured fire resistant power cablesDetail:
Ranges 1.5sqmm to 35sqmm are circular stranded conductors and ranges 25sqmm to 400sqmm are shaped stranded conductors. Any core colour sequence meeting regulatory requirements permitted. Resistance to Fire - Category F2. These cables conform to BS 7846 and, by reference, conform to the appropriate requirements of: BS EN 60228, BS EN 60332-1-2, BS EN 60332-3-24, BS EN 61034-2, BS EN 60754-1 and BS 6387 C,W & Z specifications. The above cables have been additionally tested to BS EN 60754-2. These cables have a rated voltage of 600/1000 V. -
BS 7846:2015
View Certificate PDF 677KBTable Number:
Table 4, Table 6, Table 5Schedule:
075/001/224Approved Range:
Armoured fire resistant power cablesDetail:
Ranges 4sqmm to 35sqmm are circular stranded conductors and ranges 25sqmm to 400sqmm are shaped stranded conductors. Any core colour sequence meeting regulatory requirements permitted. Resistance to Fire - Category F120. These cables conform to BS 7846 and, by reference, conform to the appropriate requirements of: BS EN 60228, BS EN 60332-1-2, BS EN 60332-3-24, BS EN 61034-2, BS EN 60754-1, BS 8491 and BS 6387 C,W & Z specifications. These cables have a rated voltage of 600/1000 V. -
IEC 60502-2:2014
View Certificate PDF 769KBTable Number:
Table N/ASchedule:
075/001/225Approved Range:
Medium voltage power cables up to 33kVDetail:
Circular stranded plain copper or aluminium conductors (class 2), extruded cross-linkable semi-conducting conductor screen, extruded cross-linkable polyethylene (XLPE) insulation, extruded cross-linkable semi-conducting bonded or strippable insulation screen, copper tape and/or copper wire screened, extruded low smoke non-halogen (LSNH ST8) separation sheath, aluminium wire armour for single core cables and galvanized steel wire armour for three core cables, extruded low smoke non-halogen (LSNH ST8) oversheath. The cables' design, materials, and testing conform to IEC 60502-2 (Generally), IEC 60228, IEC 60502-1 (for LSNH ST8 material), IEC 60332-1-2, IEC 60332-3-24, IEC 61034-2 and IEC 60754-1, IEC 60754-2, IEC 60684-2 up to 18/30 (36) kV. The cables have a rated voltage ? 3.8/6.6 (7.2)kV; 6.35/11 (12) kV; 8.7/15 (17.5) kV; 12.7/22 (24)kV and 19/33 (36)kV. -
IEC 60502-2:2014
View Certificate PDF 804KBTable Number:
Table N/ASchedule:
075/001/226Approved Range:
Medium voltage power cables up to 33kVDetail:
Circular stranded plain copper or aluminium conductors (class 2), extruded cross-linkable semi-conducting conductor screen, extruded cross-linkable polyethylene (XLPE) insulation, extruded cross-linkable semi-conducting bonded or strippable insulation screen, copper tape and/or copper wire screened, extruded polyvinyl chloride (PVC ST2) separation sheath, aluminium wire armour for single core cables and galvanized steel wire armour for three core cables, polyvinyl chloride (PVC ST2) oversheath. The cables' design, materials, and testing conform to IEC 60502-2, IEC 60228. The cables have a rated voltage ? 3.8/6.6 (7.2)kV; 6.35/11 (12) kV; 8.7/15 (17.5) kV; 12.7/22 (24)kV and 19/33 (36)kV. -
BS 8592:2016
View Certificate PDF 599KBTable Number:
Table 2Schedule:
075/001/227Approved Range:
Single core fire resistant cablesDetail:
These cables conform to BS 8592, and by reference, conform to the appropriate requirements of: BS EN 60228, BS EN 60332-1-2, BS EN 61034-2, BS EN 60754-1 and IEC 60331-3. Additionally tested to BS 6387:2013 CWZ, BS EN 50200:2015 PH120 (120 mins), BS EN 50200:2015 Annex E, BS 8434-2:2003+A2:2009; IEC 60331-21:1999 (all preceding tests conducted in steel conduit); BS EN 60754-2:2014. These cables have a rated voltage of 450/750 V. -
BS 7846:2015
View Certificate PDF 688KBTable Number:
Table 8Schedule:
075/001/228Approved Range:
Armoured fire resistant power cablesDetail:
Resistance to Fire - Category F2. These cables conform to BS 7846 and, by reference, conform to the appropriate requirements of: BS EN 60228, BS EN 60332-1-2, BS EN 60332-3-24, BS EN 61034-2, BS EN 60754-1 and BS 6387 C,W & Z specifications with a 2A fuse, cables of diameter not exceeding 20mm; cables of diameter exceeding 20mm subjected to the additional requirements of BS 7846:2015 Annex I. The above cables have been additionally tested to BS EN 60754-2. These cables have a rated voltage of 600/1000 V. -
BS EN 50525-2-31:2011
View Certificate PDF 570KBTable Number:
Table 4.1, Table 4.3, Table 4.4Schedule:
075/001/233Approved Range:
Single core non-sheathed cables with thermoplastic PVC insulationDetail:
These cables conform to BS EN 50525-2-31 and, by reference, conform to the appropriate requirements of BS EN 60228. These cables have a rated voltage of 450/750 V for Clause 4.1/Table B.1 and 300/500 V for Clause 4.3/Table B.3 & Clause 4.4/Table B.4. -
BS 6004:2012
View Certificate PDF 576KBTable Number:
Table 3, Table 4, Table 5Schedule:
075/001/234Approved Range:
PVC insulated and sheathed cablesDetail:
These cables conform to BS 6004 and, by reference, conform to the appropriate requirements of BS EN 60228. These cables have a rated voltage of 300/500 V. -
BS EN 50525-2-11:2011
View Certificate PDF 574KBTable Number:
Table 4.1, Table 4.2Schedule:
075/001/236Approved Range:
Flexible cables with thermoplastic PVC insulationDetail:
These cables conform to BS EN 50525-2-11 and, by reference, conform to the appropriate requirements of BS EN 60228. These cables have a rated voltage of 300/300 V for Clause 4.1/Table B.1 and 300/500V for Clause 4.2/Table B.2. -
BS EN 50525-3-41:2011
View Certificate PDF 628KBTable Number:
Table 4.1, Table 4.3, Table 4.4Schedule:
075/001/238Approved Range:
Single core non-sheathed cables with LSHF crosslinked insulationDetail:
These cables conform to BS EN 50525-3-41 and, by reference, conform to the appropriate requirements of: BS EN 60228, BS EN 60332-1-2, BS EN 61034-2, BS EN 60754-1, BS EN 60754-2 and BS EN 60684-2 specifications. These cables have rated voltages of 450/750 V for Clause 4.1/Table B.1 & Clause 4.2/Table B.2 and 300/500 V for Clause 4.3/Table B.3 & Clause 4.4/Table B.4. -
BS 7889:2012
View Certificate PDF 575KBTable Number:
Table 2, Table 3, Table 5Schedule:
075/001/240Approved Range:
Non-armoured power cables with PVC sheathingDetail:
Any core colour sequence meeting regulatory requirements. These cables conform to BS 7889 and, by reference, conform to the appropriate requirements of BS EN 60228. These cables have a rated voltage of 600/1000 V. -
BS 6622:2007 Incorporating Corrigenda Nos. 1 and 2
View Certificate PDF 673KBTable Number:
Table N/ASchedule:
075/001/241Approved Range:
Medium voltage power cables up to 33kV with PVC/MDPE sheathingDetail:
Circular stranded plain copper or aluminium conductors (class 2), extruded cross-linkable semi-conducting conductor screen, extruded cross-linkable polyethylene (XLPE GP 8) insulation, extruded cross-linkable semi-conducting bonded or strippable insulation screen, copper tape and/or copper wire screened, polyethylene (PE) separation sheath, aluminium wire armour for single core cables and galvanized steel wire armour for three core cables, extruded medium density polyethylene (MDPE TS 2) oversheath. The cables' design, materials, and testing conform to BS 6622 and BS EN 60228. The cables have a rated voltage ? 3.8/6.6 (7.2)kV; 6.35/11 (12) kV; 8.7/15 (17.5) kV; 12.7/22 (24)kV and 19/33 (36)kV. -
IEC 60502-2:2014
View Certificate PDF 715KBTable Number:
Table N/ASchedule:
075/001/242Approved Range:
Medium voltage power cables up to 33kVDetail:
Circular stranded plain copper or aluminium conductors (class 2), extruded cross-linkable semi-conducting conductor screen, extruded cross-linkable polyethylene (XLPE) insulation, extruded cross-linkable semi-conducting bonded or strippable insulation screen, copper tape and/or copper wire screened, extruded polyethylene (PE ST7) separation sheath, aluminium wire armour for single core cables and galvanized steel wire armour for three core cables, extruded medium density polyethylene (MDPE ST7) oversheath. The cables' design, materials, and testing conform to IEC 60502-2, IEC 60228. The cables have a rated voltage ? 3.8/6.6 (7.2)kV; 6.35/11 (12) kV; 8.7/15 (17.5) kV; 12.7/22 (24)kV and 19/33 (36)kV.
Quality (ISO 9001)
-
CS1-129
View Certificate PDF 193KBScope:
The Design, Development, Manufacture and Supply of the following cable types: Electric Wires, Energy Cables, Control Cables, Fire Resistant Cables and Branch Cables rated up to 1.2 kV, Medium Voltage Cables with Thermoset Insulation up to 36 kV. Telecommunications Cables up to 100 pairs, Category 5 Cables to 5E and frequency up to 150 MHz Materials used: Copper, Aluminium, GSW, PE, PVC, XLPE, Low Smoke Halogen Free and Elastomeric Compounds . The Development and Manufacture of PVC Compounds.
BASEC PCR
-
PCR-129
View Certificate PDF 181KBScope:
The Design, Development, Manufacture and Supply of the following cable types: Electric Wires, Energy Cables, Control Cables and Fire Resistant Cables rated up to 1.2 kV & Medium Voltage Cables with Thermoset Insulation up to 36 kV. Materials used: Copper, Aluminium, GSW, PE, PVC, XLPE, Low Smoke Halogen Free and Elastomeric Compounds.