Dongguan Keystone Electric Wire & Cable Co., Ltd Visit Website

Origin Mark:
<KEYSTONE>
Dongguan Keystone Electric Wire & Cable Co., Ltd
Ye Sha Management District,
Shatian,
Dongguan City,
523998,
Guangdong,
China
Telephone:
00867 698886723
Products (Filtered of )
-
BS 6231:2006 Incorporating Corrigendum No.1
View Certificate PDF 606KBTable Number:
Table 2Schedule:
075/001/180Approved Range:
Single core non-sheathed cables with thermoplastic PVC insulationDetail:
The above cables conform to BS 6231 and, by reference, conform to the appropriate requirements of BS EN 60228. These cables have a rated voltage of 600/1000 V. -
BS 7919:2001 Incorporating Amendment Nos. 1, 2 and
View Certificate PDF 610KBTable Number:
Table 40Schedule:
075/001/188Approved Range:
Industrial flexible cablesDetail:
These cables conform to BS 7919 and, by reference, conform to the appropriate requirements of BS EN 60228. These cables have a rated voltage of 300/500 V. -
IEC 60502-1 Edition 2.1:2009
View Certificate PDF 615KBTable Number:
Table N/ASchedule:
075/001/193Approved Range:
Low voltage power cables up to 1kVDetail:
These cables conform to IEC 60502-1 and, by reference, conform to the appropriate requirements of: IEC 60228, IEC 60332-3-24 Cat C, IEC 60332-1-2, IEC 61034-2, IEC 60684-2 and IEC 60754 specifications. These cables have a rated voltage of 600/1000 V. -
IEC 60227-3:1993 Incorporating Amendment No.1 1997
View Certificate PDF 606KBTable Number:
Table 9Schedule:
075/001/194Approved Range:
Single core PVC insulated wiresDetail:
These cables conform to IEC 60227-3 and, by reference, conform to the appropriate requirements of IEC 60228. These cables have a rated voltage of 300/500 V. -
BS 6622:2007 Incorporating Corrigenda Nos. 1 and 2
View Certificate PDF 610KBTable Number:
Table N/ASchedule:
075/001/198Approved Range:
Medium voltage power cables up to 33kV with PVC/MDPE sheathingDetail:
Stranded circular copper or aluminium conductors (class 2). Extruded semi-conducting conductor screen. XLPE insulation. Bonded or strippable extruded semi-conducting insulation screen. Copper tape and/or copper wire screened. PVC or PE bedding extruded inner sheath. Galvanised steel wire armour (3-core). Aluminium wire armour (single-core). PVC Type 9 or MDPE (TS2) extruded oversheath. These cables conform to BS 6622 and, by reference, conform to the appropriate requirements of BS EN 60228. These cables have a rated voltage - 3.8/6.6(7.2)kV; 6.35/11(12)kV; 8.7/15(17.5)kV; 12.7/22(24kV) and 19/33(36)kV -
BS 7835:2007 Incorporating Corrigendum No.1
View Certificate PDF 613KBTable Number:
Table N/ASchedule:
075/001/214Approved Range:
Medium voltage power cables up to 33kV with LSHF sheathingDetail:
Stranded circular copper or aluminium conductors (class 2). Extruded semi-conducting conductor screen. XLPE insulation. Bonded or strippable extruded semi-conducting insulation screen. Copper tape and/or copper wire screened. Low smoke, non-halogen extruded inner sheath. Galvanised steel wire armour (3-core). Aluminium wire armour (single core). Low smoke, non-halogen extruded oversheath. These cables conform to BS 7835 and, by reference, conform to the appropriate requirements of BS EN 60228, BS EN 60332-3-24, BS EN 60332-1-2, BS EN 61034-2 and BS EN 60754-1 specifications. These cables have a rated voltage - 3.8/6.6(7.2)kV; 6.35/11(12)kV; 8.7/15(17.5)kV; 12.7/22(24kV) and 19/33(36)kV -
BS 7211:2012
View Certificate PDF 611KBTable Number:
Table 4Schedule:
075/001/219Approved Range:
LSHF insulated and sheathed cablesDetail:
These cables conform to BS 7211 and, by reference, conform to the appropriate requirements of BS EN 60228, BS EN 60332-1-2, BS EN 60332-3-24, BS EN 61034-2 and BS EN 60754-1 specifications. These cables have a rated voltage of 450/750 V. -
BS 7211:2012
View Certificate PDF 658KBTable Number:
Table 5Schedule:
075/001/220Approved Range:
LSHF insulated and sheathed cablesDetail:
These cables conform to BS 7211 and, by reference, conform to the appropriate requirements of BS EN 60228, BS EN 60332-1-2, BS EN 61034-2 and BS EN 60754-1 specifications. These cables have a rated voltage of 300/500 V. -
BS 7846:2015
View Certificate PDF 613KBTable Number:
Table 4, Table 6, Table 5Schedule:
075/001/221Approved Range:
Armoured fire resistant power cablesDetail:
Ranges 1.5sqmm to 35sqmm are circular stranded conductors and ranges 25sqmm to 400sqmm are shaped stranded conductors. Any core colour sequence meeting regulatory requirements permitted. Resistance to Fire - Category F2. These cables conform to BS 7846 and, by reference, conform to the appropriate requirements of: BS EN 60228, BS EN 60332-1-2, BS EN 60332-3-24, BS EN 61034-2, BS EN 60754-1 and BS 6387 C,W & Z specifications. The above cables have been additional tested to: BS EN 60754-2 and BS EN 60684-2. These cables have a rated voltage of 600/1000 V. -
BS 7846:2015
View Certificate PDF 612KBTable Number:
Table 4, Table 6, Table 5Schedule:
075/001/224Approved Range:
Armoured fire resistant power cablesDetail:
Ranges 4sqmm to 35sqmm are circular stranded conductors and ranges 25sqmm to 400sqmm are shaped stranded conductors. Any core colour sequence meeting regulatory requirements permitted. Resistance to Fire - Category F120. These cables conform to BS 7846 and, by reference, conform to the appropriate requirements of: BS EN 60228, BS EN 60332-1-2, BS EN 60332-3-24, BS EN 61034-2, BS EN 60754-1, BS 8491 and BS 6387 C,W & Z specifications. These cables have a rated voltage of 600/1000 V. -
IEC 60502-2:2014
View Certificate PDF 700KBTable Number:
Table N/ASchedule:
075/001/225Approved Range:
Medium voltage power cables up to 33kVDetail:
Up to 300sqmm nominal cross-sectional area of conductors inclusive. 3-core. Up to 800sqmm nominal cross-sectional area of conductors inclusive. single-core. XLPE Insulation. Bonded or strippable semi-conducting insulation screen. Copper tape and/or copper wire screened. Low smoke, zero halogen, extruded inner sheath. Galvanised steel round wire armoured (3 cables). Aluminium round wire armoured (1 cables). ST8 low smoke, zero halogen, extruded outer sheath. Generally to IEC 60502-2 and including IEC 60228, IEC 60332-3.24, IEC 61034, IEC 60684-2 and IEC 60754 specifications. These cables have a rated voltage - 3.8/6.6(7.2)kV; 6.35/11(12)kV; 8.7/15(17.5)kV; 12.7/22(24kV) and 19/33(36)kV -
IEC 60502-2:2014
View Certificate PDF 615KBTable Number:
Table N/ASchedule:
075/001/226Approved Range:
Medium voltage power cables up to 33kVDetail:
Up to 300sqmm nominal cross-sectional area of conductors inclusive. 3-core. Up to 800sqmm nominal cross-sectional area of conductors inclusive. single-core. Conductor to IEC 60228. XLPE Insulation. Bonded or strippable semi-conducting insulation screen. Copper tape and/or copper wire screened. PVC or PE extruded inner sheath. Galvanised steel round wire armoured (3 cables). Aluminium round wire armoured (1 cables). PVC (ST2) or MDPE (ST7) extruded outer sheath. These cables conform to IEC 60502-2 and, by reference, conform to the appropriate requirements of IEC 60228. These cables have a rated voltage - 3.8/6.6(7.2)kV; 6.35/11(12)kV; 8.7/15(17.5)kV; 12.7/22(24kV) and 19/33(36)kV -
BS 8592:2016
View Certificate PDF 620KBTable Number:
Table 2Schedule:
075/001/227Approved Range:
Single core fire resistant cablesDetail:
These cables conform to BS 8592, and by reference, conform to the appropriate requirements of: BS EN 60228, BS EN 60332-1-2, BS EN 61034-2, BS EN 60754-1 and IEC 60331-2. Additionally tested to BS 6387:2013 CWZ, BS EN 50200:2015 PH120 (120 mins), BS EN 50200:2015 Annex E, BS 8434-2:2003+A2:2009; IEC 60331-21:1999 (all preceding tests conducted in steel conduit); BS EN 60754-2:2014. These cables have a rated voltage of 450/750 V. -
BS 7846:2015
View Certificate PDF 613KBTable Number:
Table 8Schedule:
075/001/228Approved Range:
Armoured fire resistant power cablesDetail:
Resistance to Fire - Category F2. These cables conform to BS 7846 and, by reference, conform to the appropriate requirements of: BS EN 60228, BS EN 60332-1-2, BS EN 60332-3-24, BS EN 61034-2, BS EN 60754-1 and BS 6387 C,W & Z specifications with a 2A fuse, cables of diameter not exceeding 20mm; cables of diameter exceeding 20mm subjected to the additional requirements of BS 7846:2015 Annex I. The above cables have been additional tested to: BS EN 60754-2 and BS EN 60684-2. These cables have a rated voltage of 600/1000 V. -
BS 5467:2016 Incorporating Corrigendum No. 1
View Certificate PDF 611KBTable Number:
Table 5, Table 7, Table 6Schedule:
075/001/231Approved Range:
Armoured power cables with PVC sheathingDetail:
Ranges 1.5sqmm to 120sqmm are circular stranded conductors and ranges 25sqmm to 400sqmm are shaped stranded conductors. Any core colour sequence meeting regulatory requirements permitted. These cables conform to BS 5467 and, by reference, conform to appropriate requirements of BS EN 60228. These cables have a rated voltage of 600/1000 V. -
BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2
View Certificate PDF 622KBTable Number:
Table 5, Table 7, Table 6Schedule:
075/001/232Approved Range:
Armoured power cables with LSHF sheathingDetail:
Ranges 1.5sqmm to 120sqmm are circular stranded conductors and ranges 25sqmm to 400sqmm are shaped stranded conductors. Any core colour sequence meeting regulatory requirements permitted. These cables conform to BS 6724 and, by reference, conform to appropriate requirements of BS EN 60228, BS EN 60332-1-2, BS EN 60332-3-24, BS EN 61034-2 and BS EN 60754-1. These cables have a rated voltage of 600/1000 V. -
BS EN 50525-2-31:2011
View Certificate PDF 606KBTable Number:
Table 4.1, Table 4.3, Table 4.4Schedule:
075/001/233Approved Range:
Single core non-sheathed cables with thermoplastic PVC insulationDetail:
These cables conform to BS EN 50525-2-31 and, by reference, conform to the appropriate requirements of BS EN 60228. These cables have a rated voltage of 450/750 V for Clause 4.1/Table B.1 and 300/500 V for Clause 4.3/Table B.3 & Clause 4.4/Table B.4. -
BS 6004:2012
View Certificate PDF 613KBTable Number:
Table 3, Table 4, Table 5Schedule:
075/001/234Approved Range:
PVC insulated and sheathed cablesDetail:
These cables conform to BS 6004 and, by reference, conform to the appropriate requirements of BS EN 60228. These cables have a rated voltage of 300/500 V. -
BS 6500:2000 Incorporating Amendment Nos. 1, 2 and
View Certificate PDF 608KBTable Number:
Table 26, Table 27Schedule:
075/001/235Approved Range:
Flexible cables with thermoplastic PVC insulationDetail:
These cables conform to BS 6500 and, by reference, conform to the appropriate requirements of BS EN 60228. These cables have rated voltages of 300/300 V for Table 26 and 300/500 V for Table 27. -
BS EN 50525-2-11:2011
View Certificate PDF 608KBTable Number:
Table 4.1, Table 4.2Schedule:
075/001/236Approved Range:
Flexible cables with thermoplastic PVC insulationDetail:
These cables conform to BS EN 50525-2-11 and, by reference, conform to the appropriate requirements of BS EN 60228. These cables have a rated voltage of 300/300 V for Clause 4.1/Table B.1 and 300/500V for Clause 4.2/Table B.2. -
BS EN 50525-3-41:2011
View Certificate PDF 754KBTable Number:
Table 4.1, Table 4.3, Table 4.4Schedule:
075/001/238Approved Range:
Single core non-sheathed cables with LSHF crosslinked insulationDetail:
These cables conform to BS EN 50525-3-41 and, by reference, conform to the appropriate requirements of: BS EN 60228, BS EN 60332-1-2, BS EN 61034-2, BS EN 60754-1, BS EN 60754-2 and BS EN 60684-2 specifications. These cables have rated voltages of 450/750 V for Clause 4.1/Table B.1 & Clause 4.2/Table B.2 and 300/500 V for Clause 4.3/Table B.3 & Clause 4.4/Table B.4. -
BS 7889:2012
View Certificate PDF 607KBTable Number:
Table 2, Table 3, Table 5Schedule:
075/001/240Approved Range:
Non-armoured power cables with PVC sheathingDetail:
Any core colour sequence meeting regulatory requirements. These cables conform to BS 7889 and, by reference, conform to the appropriate requirements of BS EN 60228. These cables have a rated voltage of 600/1000 V.
Quality (ISO 9001)
-
CS1-129
View Certificate PDF 241KBScope:
The Design, Development, Manufacture and Supply of the following cable types: Electric Wires, Energy Cables, Control Cables, Fire Resistant Cables and Branch Cables rated up to 1.2 kV, Medium Voltage Cables with Thermoset Insulation up to 36 kV. Telecommunications Cables up to 100 pairs, Category 5 Cables to 5E and frequency up to 150 MHz Materials used: Copper, Aluminium, GSW, PE, PVC, XLPE, Low Smoke Halogen Free and Elastomeric Compounds . The Development and Manufacture of PVC Compounds.
BASEC PCR
-
PCR-129
View Certificate PDF 183KBScope:
The Design, Development, Manufacture and Supply of the following cable types: Electric Wires, Energy Cables, Control Cables and Fire Resistant Cables rated up to 1.2 kV & Medium Voltage Cables with Thermoset Insulation up to 36 kV. Materials used: Copper, Aluminium, GSW, PE, PVC, XLPE, Low Smoke Halogen Free and Elastomeric Compounds.