Keystone Electric Wire & Cable Co., Ltd. Visit Website

Origin Mark:
- KEYSTONE -

Keystone Electric Wire & Cable Co., Ltd.
#110 D.D. 83 Kwan Ti North Village
P.O. Box 376,
Fanling Post Office,
Fanling N. T.,
Hong Kong

Telephone:
008522 6917183

Products (Filtered of )

Filters (1) Edit filter

  • BS 6346:1997 Incorporating Amendment Nos. 1 and 2
    View Certificate PDF 427KB

    Table Number:
    Table 7, Table 9, Table 11

    Schedule:
    066/001/174

    Approved Range:
    Armoured power cables with PVC sheathing

    Detail:
    Note: These cables conform to BS6346 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 6346:1997 Incorporating Amendment Nos. 1 and 2
    View Certificate PDF 423KB

    Table Number:
    Table 5

    Schedule:
    066/001/175

    Approved Range:
    Armoured power cables with PVC sheathing

    Detail:
    Note : These cables conform to BS 6346 and,by refernce,conform to the appropriate requirements of BS EN 60228.

  • BS 6346:1997 Incorporating Amendment Nos. 1 and 2
    View Certificate PDF 418KB

    Table Number:
    Table 19

    Schedule:
    066/001/176

    Approved Range:
    Armoured power cables with PVC sheathing

    Detail:
    Note: These cables conform to BS 6346 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 6346:1997 Incorporating Amendment Nos. 1 and 2
    View Certificate PDF 452KB

    Table Number:
    Table 5

    Schedule:
    066/001/177

    Approved Range:
    Armoured power cables with PVC sheathing

    Detail:
    Core colour sequence - Single-core: red or black. Note: These cables conform to BS 6346 and, by reference,conform to the appropriate requirements of BS EN 60228.

  • BS 6346:1997 Incorporating Amendment Nos. 1 and 2
    View Certificate PDF 465KB

    Table Number:
    Table 7, Table 9, Table 11

    Schedule:
    066/001/178

    Approved Range:
    Armoured power cables with PVC sheathing

    Detail:
    Core colour sequence - Two-core: red, black. Three-core: red, yellow, blue. Four-core: red, yellow, blue, black. Note: These cables conform to BS 6346 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 6231:1998 Incorporating Amendment No.1
    View Certificate PDF 409KB

    Table Number:
    Table 8

    Schedule:
    066/001/179

    Approved Range:
    Single core non-sheathed cables with thermoplastic PVC insulation

    Detail:
    Note: These cables conform to BS 6231 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 6004:2000 Incorporating Amendment Nos. 1 and 2
    View Certificate PDF 505KB

    Table Number:
    Table 8

    Schedule:
    066/001/180

    Approved Range:
    PVC insulated and sheathed cables

    Detail:
    Colour of sheath: White or Grey. Core colour sequence - Single-core: red or black. Twin-core: red and black, or, or 2 x 1 and 2 x 1.5sqmm cables, red and red. Three-core: red, yellow (centre core) and blue. Position of circuit protective conductor - Twin: centrally placed between cores in

  • BS 6004:2000 Incorporating Amendment Nos. 1 and 2
    View Certificate PDF 454KB

    Table Number:
    Table 8

    Schedule:
    066/001/181

    Approved Range:
    PVC insulated and sheathed cables

    Detail:
    Colour of sheath: white or grey. Note: These cables conform to BS 6004 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 5467:2016 Incorporating Corrigendum No. 1
    View Certificate PDF 437KB

    Table Number:
    Table 4

    Schedule:
    066/001/182

    Approved Range:
    Armoured power cables with PVC sheathing

    Detail:
    Any core colour sequence meeting regulatory requirements permitted. Note: These cables conform to BS 5467 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 5467:2016 Incorporating Corrigendum No. 1
    View Certificate PDF 443KB

    Table Number:
    Table 5, Table 6, Table 7

    Schedule:
    066/001/183

    Approved Range:
    Armoured power cables with PVC sheathing

    Detail:
    Any core colour sequence meeting regulatory requirements permitted. Note: These cables conform to BS 5467 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 5467:2016 Incorporating Corrigendum No. 1
    View Certificate PDF 454KB

    Table Number:
    Table 9

    Schedule:
    066/001/184

    Approved Range:
    Armoured power cables with PVC sheathing

    Detail:
    For 5-core see note A of BS 5467:2016 Table 9. Any core colour sequence meeting regulatory requirements permitted. Note: These cables conform to BS 5467 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 5467:1997 Incorporating Amendment Nos. 1 and 2
    View Certificate PDF 436KB

    Table Number:
    Table 6, Table 8, Table 10

    Schedule:
    066/001/185

    Approved Range:
    Armoured power cables with PVC sheathing

    Detail:
    Any core colour sequence meeting regulatory requirements permitted. Note: These cables conform to BS 5467 and,by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 6004:2000 Incorporating Amendment Nos. 1 and 2
    View Certificate PDF 428KB

    Table Number:
    Table 4a

    Schedule:
    066/001/186

    Approved Range:
    PVC insulated and sheathed cables

    Detail:
    Note: These cables conform to BS6004 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 6004:2000 Incorporating Amendment Nos. 1 and 2
    View Certificate PDF 488KB

    Table Number:
    Table 7

    Schedule:
    066/001/187

    Approved Range:
    PVC insulated and sheathed cables

    Detail:
    Colour of sheath, single-core: White, grey, black, red, blue or brown. Colour of sheath, flat-twin and 3-core: White or grey. Core colour sequence - single-core: red or black. Twin-core: red and black, or, for 2 x 1 and 2 x 1.5sqmm cables, red and red. Three-core: red, yellow (centre core)

  • BS 6004:2000 Incorporating Amendment Nos. 1 and 2
    View Certificate PDF 464KB

    Table Number:
    Table 7

    Schedule:
    066/001/188

    Approved Range:
    PVC insulated and sheathed cables

    Detail:
    Colour of sheath, single-core: White, grey, black, red, blue or brown. Colour of sheath, flat twin and 3-core: White or grey. Note: These cables conform to BS 6004 and,by reference,conform to the appropriate requirements of BS EN 60228.

  • BS 7889:2012
    View Certificate PDF 436KB

    Table Number:
    Table 2

    Schedule:
    066/001/189

    Approved Range:
    Non-armoured power cables with PVC sheathing

    Detail:
    Any core colour sequence meeting regulatory requirements permitted. Note: These cables conform to BS 7889 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 7889:2012
    View Certificate PDF 439KB

    Table Number:
    Table 3, Table 4, Table 5

    Schedule:
    066/001/190

    Approved Range:
    Non-armoured power cables with PVC sheathing

    Detail:
    Any core colour sequence meeting regulatory requirements permitted. Note: These cables conform to BS 7889 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS EN 50525-2-31:2011
    View Certificate PDF 455KB

    Table Number:
    Table 4.1

    Schedule:
    066/001/191

    Approved Range:
    Single core non-sheathed cables with thermoplastic PVC insulation

    Detail:
    Note: These cables conform to BS EN 50525-2-31 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 6004:2012
    View Certificate PDF 467KB

    Table Number:
    Table 3

    Schedule:
    066/001/192

    Approved Range:
    PVC insulated and sheathed cables

    Detail:
    Note: These cables conform to BS 6004 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 6004:2012
    View Certificate PDF 471KB

    Table Number:
    Table 4

    Schedule:
    066/001/193

    Approved Range:
    PVC insulated and sheathed cables

    Detail:
    Note: These cables conform to BS 6004 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2
    View Certificate PDF 478KB

    Table Number:
    Table 9

    Schedule:
    066/001/194

    Approved Range:
    Armoured power cables with LSHF sheathing

    Detail:
    For 5-core see note A of Table 9. Any core colour sequence meeting regulatory requirements permitted. Note: These cables conform to BS 6724 and, by reference, conform to the appropriate requirements of: BS EN 60228, BS EN 60332-1-2, BS EN 60332-3-24, BS EN 61034-2,and BS EN 60754-1. These cables hav

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2
    View Certificate PDF 491KB

    Table Number:
    Table 5, Table 6, Table 7

    Schedule:
    066/001/195

    Approved Range:
    Armoured power cables with LSHF sheathing

    Detail:
    Any core colour sequence meeting regulatory requirements permitted. Note:These cables conform to BS 6724 and, by reference, conform to the appropriate requirements of: BS EN 60228, BS EN 60332-1-2, BS EN 60332-3-24 , BS EN 61034-2 and BS EN 60754-1. These cables have been additionally tested to: BS

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2
    View Certificate PDF 472KB

    Table Number:
    Table 4

    Schedule:
    066/001/196

    Approved Range:
    Armoured power cables with LSHF sheathing

    Detail:
    Any core colour sequence meeting regulatory requirements permitted. Note: These above cables conform to BS 6724 and, by reference, conform to the appropriate requirements of:BS EN 60228, BS EN 60332-1-2, BS EN 60332-3-24,BS EN 61034-2 and BS EN 60754-1. These cables have been additionally tested to:

Quality (ISO 9001)

  • CS1-102
    View Certificate PDF 449KB

    Scope:
    The design, development, manufacture and supply of the following cable types: Energy Cables rated up to 1000V, Telecommunication Cables, Data Cables.Insulating and Sheathing Compounds used in above: (PE, PP, XLPE, PVC, Low Smoke Non-Halogen). International sales, design and supply of: Energy Cables up to 36kV (including fire resistant cables). Insulating and Sheathing Compounds used in Energy Cables up to 36kV: (PE, PP, XLPE, PVC, Low Smoke Non-Halogen and Elastomeric Compounds).

BASEC PCR

  • PCR-102
    View Certificate PDF 410KB

    Scope:
    The design, development, manufacture and supply of the following cable types: Electric Wires and Energy Cables rated up to 1000V. Insulating and Sheathing Compounds used in above: XLPE, PVC, Low Smoke Non-Halogen).