JLY Group Company Ltd.

Licence Number:
202

Origin Mark:
JLY GROUP CO., LTD. or TRICIRCLE or HILLY

JLY Group Company Ltd.
288 Jihua Road
Buji, Shenzhen
Guangdong - 518112
China

Telephone:
+ 86 755 28522888

Product Schedule

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    202/001/039

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.5sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - TI1.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.2 Table B.2

    Schedule:
    202/001/040

    Approved Range:
    1.5sqmm to 240sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - TI1.

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    202/001/041

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.5sqmm to 240sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - EI5.

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.2 Table B.2

    Schedule:
    202/001/042

    Approved Range:
    1.5sqmm to 240sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - EI5.

  • BS 6004:2012

    Table Number:
    Table 3

    Schedule:
    202/001/043

    Approved Range:
    1.0sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Single-core to 3-core inclusive. Class 1 conductor. 4sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. 4sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Twin-core to 3-core inclusive. Class 2 conductor. Sheath - Type 6. Insulation - TI1.

  • BS 6004:2012

    Table Number:
    Table 4

    Schedule:
    202/001/044

    Approved Range:
    1.0sqmm to 1.5sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.0sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Twin-core to 3-core inclusive. Class 1 conductor. 4sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Twin-core to 3-core inclusive. Class 2 conductor. Sheath - Type 6. Insulation - TI1.

  • BS 8592:2016

    Table Number:
    Table 2

    Schedule:
    202/001/051

    Approved Range:
    1.5sqmm to 70sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. BS 6387:2013 CWZ. Insulation - EI5.

  • BS 7846:2015

    Table Number:
    Tables 4, 5, 6, 7 & 8

    Schedule:
    202/001/052

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Two core to four core inclusive. 1.5sqmm to 70 sqmm nominal cross-sectional area of conductors inclusive. 5-core. 1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 37-core inclusive. Sheath - LTS1. Insulation - GP8. Resistance to fire Category F2. Tested bend radius 8D.

  • BS 5467:2016 Incorporating Corrigendum No. 1

    Table Number:
    Table 4

    Schedule:
    202/001/053

    Approved Range:
    50sqmm to 1000sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Sheath - Type 9. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No. 1

    Table Number:
    Table 9

    Schedule:
    202/001/055

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 37-core inclusive. Class 2 conductor. Sheath - Type 9. Insulation - GP8.

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2

    Table Number:
    Table 4

    Schedule:
    202/001/056

    Approved Range:
    50sqmm to 1000sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Sheath - LTS1. Insulation - GP8.

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2

    Table Number:
    Tables 5, 6, 7 and 8

    Schedule:
    202/001/057

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. 1.5sqmm to 70sqmm nominal cross-section are of conductors inclusive. Five-core. Class 2 conductor. Sheath - LTS1. Insulation - GP8.

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2

    Table Number:
    Table 9

    Schedule:
    202/001/058

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 37-core inclusive. Class 2 conductor. Sheath - LTS1. Insulation - GP8.

Quality (ISO 9001)

  • CS1-246

    Scope:
    Plastic insulated screened and un-screened control cables. PVC insulated un-sheathed cable of rated voltage 450/750V and below. PVC insulated and PVC sheathed cables. PVC insulated and PVC sheathed flexible cables. Armoured and non-armoured power Cable of rated voltage 1KV and 3KV. Pre-fabricated branch cable. LSHF flame retardant power cable. Fire resistant power cable. Flame retardant power cable. Compounding of polymers. Drum reel assembly.

BASEC PCR

  • PCR-246

    Scope:
    Single core non-sheathed cables with thermoplastic PVC insulation of rated voltage 450/750V. Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke of rated voltage 450/750V. PVC insulated and PVC sheathed cables for voltage 300/500V. Thermosetting insulated, armoured cables for voltages of 600/1000V with PVC oversheath or low emission of smoke and corrosive gases oversheath. Thermosetting insulated, armoured, fire resistant cables of rated voltage 600/1000V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Fire-resistant, single core non-sheathed cables with halogen-free crosslinked insulation of rate voltage 450/750V.

CPR