Ebion Kablo Sanayi Ticaret Anonim Sirketi Visit Website

Licence Number:
191

Origin Mark:
ebion kablo or EB or EUROCAB or EXCEL

Ebion Kablo Sanayi Ticaret Anonim Sirketi
Haci Eyuplu Mah.
3128 Sok. No: 7 Ucler
Denizli
Turkey

Telephone:
+90 258 371 3790

Product Schedule

  • BS 6004:2012

    Table Number:
    Table 3

    Schedule:
    191/001/055

    Approved Range:
    1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 4sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Sheath - Type 6. Insulation - TI1.

  • BS 6004:2012

    Table Number:
    Table 4

    Schedule:
    191/001/056

    Approved Range:
    1sqmm to 1.5sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat twin to flat 3-core inclusive. Class 1 conductor. 4sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat twin to flat 3-core inclusive. Class 2 conductor. Sheath - Type 6. Insulation - TI1.

  • BS 7211:2012

    Table Number:
    Table 5

    Schedule:
    191/001/057

    Approved Range:
    1sqmm to 1.5sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat twin. Class 1 & 2 conductor. 1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat 3-core. Class 2 conductor. 4sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat twin to flat 3-core inclusive. Class 2 conductor. Sheath - LTS2. Insulation - GP8.

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.2 Table B.2

    Schedule:
    191/001/059

    Approved Range:
    1.5sqmm to 240sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - EI5.

  • BS 5467:1997 and A3:2008

    Table Number:
    Table 4

    Schedule:
    191/001/060

    Approved Range:
    50sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Single-core. Sheath - Type 9. Insulation - GP8.

  • BS 6724:1997 and A3:2008

    Table Number:
    Table 4

    Schedule:
    191/001/061

    Approved Range:
    50sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Single-core. Sheath - LTS1. Insulation - GP8.

  • BS 5467:1997 and A3:2008

    Table Number:
    Tables 6, 8, 10 and 13

    Schedule:
    191/001/062

    Approved Range:
    1.5sqmm to 300sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. 1.5sqmm to 70sqmm nominal cross-sectional area of conductors inclusive. Five-core. Sheath - Type 9. Insulation - GP8.

  • BS 6724:1997 and A3:2008

    Table Number:
    Tables 6, 8, 10 and 13

    Schedule:
    191/001/063

    Approved Range:
    1.5sqmm to 300sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. 1.5sqmm to 70sqmm nominal cross-sectional area of conductors inclusive. five-core. Sheath - LTS1. Insulation - GP8.

  • BS 5467:1997 and A3:2008

    Table Number:
    Table 18

    Schedule:
    191/001/064

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 48-core inclusive. Sheath - Type 9. Insulation - GP8.

  • BS 6724:1997 and A3:2008

    Table Number:
    Table 18

    Schedule:
    191/001/065

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 48-core inclusive. Sheath - LTS1. Insulation - GP8.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    191/001/066

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.5sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - TI1.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.2 Table B.2

    Schedule:
    191/001/067

    Approved Range:
    1.5sqmm to 240sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - TI1.

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    191/001/068

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. Insulation - EI5. 1.5sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - EI5.

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.4 Table B.4

    Schedule:
    191/001/069

    Approved Range:
    .5sqmm to 1sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation -EI5.

  • BS 6004:2012

    Table Number:
    Table 6

    Schedule:
    191/001/070

    Approved Range:
    0.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. Circular 2-core. 0.75sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 3-core to 5-core inclusive. Class 5. Sheath - Type 10. Insulation - TI4.

Quality (ISO 9001)

  • CS1-241

    Scope:
    The design, developement, manufacture, sales and supply of the following Cable types and products: Low Voltage Cables, PVC, XLPE and Low Smoke Halogen Free Insulation. PVC, Low Smoke Halogen Free Sheathed Armoured and Non-Armoured Cables for Voltages up to and including 0.6/1.0 kV. Manufacture of: PVC Compound

BASEC PCR

  • PCR-241

    Scope:
    The design, development, manufacture, sales and supply of the following cable types and products: Low Voltage Cables, PVC, XLPE and Low Smoke Halogen Free Insulation. PVC, Low smoke Halogen Free Sheathed Armoured and Non-Armoured Cables for Voltages up to and including 0.6/1.0 kV. Manufacture of: PVC Compound

CPR