Product Schedule

  • BS 6724:1997 and A3:2008

    Table Number:
    Tables 6, 8, 10 and 13

    Schedule:
    164/001/043

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. 1.5sqmm to 70sqmm nominal cross-sectional area of conductors inclusive. Five-core. Sheath - LTS1. Insulation - GP8.

  • BS 5467:1997 and A3:2008

    Table Number:
    Table 18

    Schedule:
    164/001/044

    Approved Range:
    1.5sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. 7-core to 37-core inclusive. Sheath - Type 9. Insulation - GP8.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    164/001/047

    Approved Range:
    1.5sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - TI1.

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    164/001/048

    Approved Range:
    1.5sqmm to 300sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - EI5.

  • BS EN 50525-2-11:2011

    Table Number:
    Clause 4.2 Table B.2

    Schedule:
    164/001/049

    Approved Range:
    0.75sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. 2-core to 5-core inclusive. Class 5 conductor. Circular cables. Sheath - TM2. Insulation - TI2.

  • BS 7211:2012

    Table Number:
    Table 3

    Schedule:
    164/001/050

    Approved Range:
    1.0sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Single-core. Sheath - LTS4. Insulation - GP8.

  • BS 5467:1997 and A3:2008

    Table Number:
    Table 4

    Schedule:
    164/001/051

    Approved Range:
    50sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. Sheath - Type 9. Insulation - GP8.

  • BS 6724:1997 and A3:2008

    Table Number:
    Table 4

    Schedule:
    164/001/052

    Approved Range:
    50sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. Sheath - LTS1. Insulation - GP8.

  • BS 6724:1997 and A3:2008

    Table Number:
    Table 18

    Schedule:
    164/001/053

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 12-core inclusive. Sheath - LTS1. Insulation - GP8.

  • BS 5467:1997 and A3:2008

    Table Number:
    Tables 6, 8, 10 & 13

    Schedule:
    164/001/054

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. 1.5sqmm to 70sqmm nominal cross-sectional area of conductors inclusive. Five-core. Sheath - Type 9. Insulation - GP8.

  • BS 7211:2012

    Table Number:
    Table 5

    Schedule:
    164/001/056

    Approved Range:
    1.0sqmm to 1.5sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1. 1.0sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat twin. Class 1. 1.0 to 2.5sqmm nominal cross-sectional area of conducors inclusive. Flat 3-core. Class 1. 1.0sqmm to 16sqmm nominal cross-sectional area of conductors includive. Flat twin. Class 2. 4.0sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat 3-core. Class 2. Sheath - LTS2. Insulation - GP8.

  • BS 6004:2012

    Table Number:
    Table 6

    Schedule:
    164/001/057

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 3-core. 1.5sqmm nominal cross-sectional area of conductor. 2-core. Sheath - Type 10. Insulation - TI4.

  • BS 6004:2012

    Table Number:
    Table 3

    Schedule:
    164/001/058

    Approved Range:
    1.0sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Single-core to 3-core inclusive. Class 1 conductor. 4sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Single-core to 3-core inclusive. Class 2 conductor. 25sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Sheath - Type 6. Insulation - TI1.

  • BS 6004:2012

    Table Number:
    Table 4

    Schedule:
    164/001/059

    Approved Range:
    1.0sqmm to 1.5sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.0sqmm to 2.5sqmm nominal cross-sectional area of conductor. Flat twin to flat 3-core inclusive. Class 1 conductor. 4sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat twin to flat 3-core inclusive. Class 2 conductor. Sheath - Type 6. Insulation - TI1.

BASEC PCR

  • PCR-217

    Scope: