Pamukkale Kablo Sanayi Ve Ticaret A.S. Visit Website

Licence Number:
164

Origin Mark:
PK or PAMUKKALE KABLO

Pamukkale Kablo Sanayi Ve Ticaret A.S.
Hacieyuplu Mah. Menderes Bulvari No:5
Merkezefendi Denizli
Turkey

Telephone:
+90 258 371 26 10

Products (Filtered of )

Filters (1) Edit filter

  • BS EN 50525-2-31:2011
    View Certificate PDF 428KB

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    164/001/047

    Approved Range:
    1.5sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - TI1.

  • BS EN 50525-3-41:2011
    View Certificate PDF 441KB

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    164/001/048

    Approved Range:
    1.5sqmm to 300sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - EI5.

  • BS EN 50525-2-11:2011
    View Certificate PDF 432KB

    Table Number:
    Clause 4.2 Table B.2

    Schedule:
    164/001/049

    Approved Range:
    0.75sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. 2-core to 5-core inclusive. Class 5 conductor. Circular cables. Sheath - TM2. Insulation - TI2.

  • BS 7211:2012
    View Certificate PDF 426KB

    Table Number:
    Table 3

    Schedule:
    164/001/050

    Approved Range:
    1.0sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Single-core. Sheath - LTS4. Insulation - GP8.

  • BS 7211:2012
    View Certificate PDF 467KB

    Table Number:
    Table 5

    Schedule:
    164/001/056

    Approved Range:
    1.0sqmm to 1.5sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1. 1.0sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat twin. Class 1. 1.0 to 2.5sqmm nominal cross-sectional area of conducors inclusive. Flat 3-core. Class 1. 1.0sqmm to 16sqmm nominal cross-sectional area of conductors includive. Flat twin. Class 2. 4.0sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat 3-core. Class 2. Sheath - LTS2. Insulation - GP8.

  • BS 6004:2012
    View Certificate PDF 438KB

    Table Number:
    Table 6

    Schedule:
    164/001/057

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 3-core. 1.5sqmm nominal cross-sectional area of conductor. 2-core. Sheath - Type 10. Insulation - TI4.

  • BS 6004:2012
    View Certificate PDF 456KB

    Table Number:
    Table 3

    Schedule:
    164/001/058

    Approved Range:
    1.0sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Single-core to 3-core inclusive. Class 1 conductor. 4sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Single-core to 3-core inclusive. Class 2 conductor. 25sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Sheath - Type 6. Insulation - TI1.

  • BS 6004:2012
    View Certificate PDF 458KB

    Table Number:
    Table 4

    Schedule:
    164/001/059

    Approved Range:
    1.0sqmm to 1.5sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.0sqmm to 2.5sqmm nominal cross-sectional area of conductor. Flat twin to flat 3-core inclusive. Class 1 conductor. 4sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat twin to flat 3-core inclusive. Class 2 conductor. Sheath - Type 6. Insulation - TI1.

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2
    View Certificate PDF 266KB

    Table Number:
    Table 5, 6, 7 and 8

    Schedule:
    164/001/060

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. 1.5sqmm to 70 sqmm nominal cross-sectional area of conductors inclusive. Five-core. Sheath - LTS1. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No. 1
    View Certificate PDF 265KB

    Table Number:
    Table 9

    Schedule:
    164/001/061

    Approved Range:
    1.5sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. 7-core to 37-core inclusive. Sheath - Type 9. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No. 1
    View Certificate PDF 265KB

    Table Number:
    Table 4

    Schedule:
    164/001/062

    Approved Range:
    50sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. Sheath - Type 9. Insulation - GP8.

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2
    View Certificate PDF 265KB

    Table Number:
    Table 4

    Schedule:
    164/001/063

    Approved Range:
    50sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. Sheath - LTS1. Insulation - GP8.

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2
    View Certificate PDF 265KB

    Table Number:
    Table 9

    Schedule:
    164/001/064

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 12-core inclusive. Sheath - LTS1. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No. 1
    View Certificate PDF 265KB

    Table Number:
    Tables 5, 6, 7 and 8

    Schedule:
    164/001/065

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. 1.5sqmm to 70sqmm nominal cross-sectional area of conductors inclusive. Five-core. Sheath - Type 9. Insulation - GP8.

BASEC PCR

  • PCR-217
    View Certificate PDF 1.1MB

    Scope:
    The design, manufacture and sales of: Low Voltage Building Wires up to and including 450/750V and Low Smoke Halogen-Free materials. Flexible PVC Cables up to 300/500V. Low Voltage Armoured Power Cables up to 1kV with PVC and Low Smoke Halogen-Free materials. The manufacture of: PVC Compounds.