Oman Cables Industry (SAOG) Visit Website

Licence Number:
158

Origin Mark:
OMAN CABLES

Oman Cables Industry (SAOG)
P.O. Box No. 25
Rusayl
Postal Code - 124
Sultanate of Oman

Product Schedule

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    158/001/070

    Approved Range:
    1.5sqmm to 1000sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 & 2 conductor. Insulation - TI1.

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    158/001/071

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.5sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - EI5.

  • BS 7889:2012

    Table Number:
    Table 2

    Schedule:
    158/001/072

    Approved Range:
    1.5sqmm to 1000sqmm nominal cross-sectional area of conductors inclusive. Single-core. Sheath - Type 9. Insulation - GP8.

  • BS 6004:2012

    Table Number:
    Table 3

    Schedule:
    158/001/073

    Approved Range:
    1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Single-core, flat twin & flat 3-core inclusive. Class 1 conductor. 4sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. 4sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat twin to flat 3-core inclusive. Class 2 conductor. Sheath - Type 6. Insulation - TI1.

  • BS 7846:2015

    Table Number:
    Table 4

    Schedule:
    158/001/077

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Two core. Resistance to fire - Category F2. Sheath - LTS1. Insulation - GP8.

  • BS 7846:2015

    Table Number:
    Table 5

    Schedule:
    158/001/078

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Three core. Resistance to fire - Category F2. Sheath - LTS1. Insulation - GP8.

  • BS 7846:2015

    Table Number:
    Table 6

    Schedule:
    158/001/079

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Four core. Resistance to fire - Category F2. Sheath - LTS1. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No. 1

    Table Number:
    Table 4

    Schedule:
    158/001/080

    Approved Range:
    50sqmm to 1000sqmm nominal cross-sectional area of conductors inclusive. Single-core. Sheath - Type 9. Insulation - GP8.

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2

    Table Number:
    Table 4

    Schedule:
    158/001/081

    Approved Range:
    50sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. Sheath - LTS1. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No. 1

    Table Number:
    Table 6

    Schedule:
    158/001/082

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Three-core. Sheath - Type 9. Insulation - GP8.

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2

    Table Number:
    Table 7

    Schedule:
    158/001/083

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Four-core. Sheath - LTS1. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No. 1

    Table Number:
    Table 7

    Schedule:
    158/001/084

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Four-core. Sheath - Type 9. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No. 1

    Table Number:
    Table 8

    Schedule:
    158/001/085

    Approved Range:
    1.5sqmm to 70sqmm nominal cross-sectional area of conductors inclusive. Five-core. Sheath - Type 9. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No. 1

    Table Number:
    Table 9

    Schedule:
    158/001/086

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 37-core inclusive. Sheath - Type 9. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No. 1

    Table Number:
    Table 5

    Schedule:
    158/001/087

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Two-core. Sheath - Type 9. Insulation - GP8.

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2

    Table Number:
    Table 5

    Schedule:
    158/001/088

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Two-core. Sheath - LTS1. Insulation - GP8.

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2

    Table Number:
    Table 6

    Schedule:
    158/001/089

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Three-core. Sheath - LTS1. Insulation - GP8.

Quality (ISO 9001)

  • CS1-214

    Scope:
    The design, manufacture and supply of the following cable types: Medium Voltage Power Cables up to 33kV, Low Voltage Power Cables up to 3.3kV, Control Cables, Instrumentation Cables, Pilot Cables, Building Wires and Flexible Cords, Aerial Bunched Cables, Overhead Lines Conductors (Bare and Insulated), Other Wires and Cables for Electrical Power and Control Applications, Fire Integrity LV Power Cables and PVC Compounds.

BASEC PCR

  • PCR-214

    Scope:
    The design, manufacture and supply of the following cable types: Medium Voltage Power Cables up to 33kV, Low Voltage Electrical Power Cables, Building Wires and Flexible Cords, Control Cables, Other Wires and Cables for Electrical Power and Control Applications, Fire Integrity LV Power Cables and PVC Compounds.

CPR