Nexans Turkiye Endustri ve Ticaret A.S. Visit Website

Licence Number:
081

Origin Mark:
NEXANS i or NEXANS i )( or )( or 126/001

Nexans Turkiye Endustri ve Ticaret A.S.
Bozburun Mahallesi
Ahmet Nuri Erikoglu Caddesi No.2
Denizli
Turkey

Telephone:
00 90 258 371 21 80

Product Schedule

  • BS 7889:2012

    Table Number:
    Table 2

    Schedule:
    081/001/175

    Approved Range:
    50sqmm to 1000sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Sheath - Type 9. Insulation - GP8.

  • BS EN 50525-2-11:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    081/001/176

    Approved Range:
    0.5sqmm to 0.75sqmm nominal cross-sectional area of conductors inclusive. 2-core to 4-core inclusive. Circular cables. 0.5sqmm to 0.75sqmm nominal cross-sectional area of conductors inclusive. 2-core. Flat cables. Class 5 conductor. Sheath - TM2. Insulation - TI2.

  • BS EN 50525-2-11:2011

    Table Number:
    Clause 4.2 Table B.2

    Schedule:
    081/001/177

    Approved Range:
    0.75sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 2-core to 54-core inclusive. Circular cables. 0.75sqmm to 1.5sqmm nominal cross-sectional area of conductors inclusive. 2-core. Flat cables. Class 5 conductor. Sheath - TM2. Insulation - TI2.

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    081/001/178

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.5sqmm to 300sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - EI5.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    081/001/179

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.5sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - TI1.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.2 Table B.2

    Schedule:
    081/001/180

    Approved Range:
    1.5sqmm to 240sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - TI1.

  • BS 7889:2012

    Table Number:
    Table 2

    Schedule:
    081/001/182

    Approved Range:
    1.5sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Sheath - Type 9. Insulation - GP8.

  • BS 7846:2015

    Table Number:
    Tables 4, 5 and 6

    Schedule:
    081/001/183

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Two core to four core inclusive. Resistance to Fire Category F2. Sheath - LTS1. Insulation - GP8.

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2

    Table Number:
    Table 9

    Schedule:
    081/001/184

    Approved Range:
    1.5sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. 7-core to 37-core inclusive. Sheath - LTS1. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No. 1

    Table Number:
    Table 9

    Schedule:
    081/001/185

    Approved Range:
    1.5sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. 7-core to 37-core inclusive. Sheath - Type 9. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No. 1

    Table Number:
    Table 4

    Schedule:
    081/001/186

    Approved Range:
    50sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. Sheath - Type 9. Insulation - GP8.

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2

    Table Number:
    Table 8

    Schedule:
    081/001/187

    Approved Range:
    1.5sqmm to 70sqmm nominal cross-sectional area of conductors inclusive. Five-core. Sheath - LTS 1. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No. 1

    Table Number:
    Table 8

    Schedule:
    081/001/188

    Approved Range:
    1.5sqmm to 70sqmm nominal cross-sectional area of conductors inclusive. Five-core. Sheath - Type 9. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No. 1

    Table Number:
    Tables 5, 6 and 7

    Schedule:
    081/001/189

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. Sheath - Type 9. Insulation - GP8.

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2

    Table Number:
    Tables 5, 6 and 7

    Schedule:
    081/001/190

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. Sheath - LTS1. Insulation - GP8.

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2

    Table Number:
    Table 4

    Schedule:
    081/001/191

    Approved Range:
    50sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. Sheath - LTS1. Insulation - GP8.

Quality (ISO 9001)

  • CS1-139

    Scope:
    The design, manufacture and supply of the following cable types and products: Low Voltage Installation Cables. Equipment Cables. Medium Voltage Power Cables up to 66kV. Materials: PVC, PE, XLPE, Cu and Steel Wire. PVC and LSHF Compounding

BASEC PCR

  • PCR-139

    Scope:
    The design, manufacture and supply of the following cable types and products: Low Voltage Installation Cables. Equipment Cables. Medium Voltage Power Cables up to 66kV. Materials: PVC, PE, XLPE, Cu and Steel Wire. PVC and LSHF Compounding