Tratos (UK) Limited Visit Website

Licence Number:
048

Origin Mark:
x TRATOS x

Tratos (UK) Limited
Randles Road
Knowsley, Mersyeside
United Kingdom

Telephone:
0151 548 3888

Product Schedule

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.2 Table B.2

    Schedule:
    048/001/206

    Approved Range:
    1.5sqmm to 6sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - EI5.

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    048/001/207

    Approved Range:
    1.5sqmm to 6sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - EI5.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    048/001/208

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.5sqmm to 120sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - TI1.

  • BS 6004:2012

    Table Number:
    Table 3

    Schedule:
    048/001/209

    Approved Range:
    1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Single-core to flat 3-core inclusive. Class 1 conductor. 4sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. 4sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat twin to flat 3-core inclusive. Class 2 conductor. Sheath - Type 6. Insulation - TI1.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.2 Table B.2

    Schedule:
    048/001/210

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - TI1.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.2 Table B.2

    Schedule:
    048/001/211

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - TI1.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.3 Table B.3

    Schedule:
    048/001/212

    Approved Range:
    1sqmm nominal cross-sectional area of conductor. Single-core. Class 1 conductor. Insulation - TI1.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.4 Table B.4

    Schedule:
    048/001/213

    Approved Range:
    0.5sqmm to 1sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - TI1.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.4 Table B.4

    Schedule:
    048/001/214

    Approved Range:
    0.5sqmm to 1sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - TI1.

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.2 Table B.2

    Schedule:
    048/001/215

    Approved Range:
    1.5sqmm to 6sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - EI5.

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    048/001/216

    Approved Range:
    1.5sqmm to 6sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - EI5.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    048/001/217

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.5sqmm to 120sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - TI1.

  • BS 5467:1997 and A3:2008

    Table Number:
    Tables 6, 8 and 10

    Schedule:
    048/001/218

    Approved Range:
    1.5sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. Sheath - Type 9. Insulation - GP8.

Quality (ISO 9001)

  • CS1-043

    Scope:
    The design, manufacture and supply of the following cable types and products: Flexible Cables and Cords. Instrumentation and Control Cables. Power Cables Rated up to 600/1000V, using the following Insulation and Sheathing Materials: PVC, PE, TPE, XLPE, Fluoropolymer and Low Smoke & Fume Zero Halogen.

Environmental (ISO 14001)

  • ECS-044

    Scope:
    Management and Control of an Environmental System in respect of the activities at the above site employed in the design, manufacture and supply of the following cable types and products: Flexible Cables and Cords, Instrumentation and Control Cables, Power Cables Rated up to 600/1000V, using the following Insulation and Sheathing Materials: PVC, PE, TPE, XLPE, Fluoropolymer and Low Smoke & Fume Zero Halogen.

Health & Safety (OHSAS 18001)

  • HS-111

    Scope:
    Management and Control of an Occupational Health & Safety System in respect of the activities at the above site employed in the design, manufacture and supply of the following cables types and products:Flexible Cables and Cords, Instrumentation and Control Cables, Power Cables rated up to 600/1000V, using the following Insulation and Sheathing Materials: PVC, PE, TPE, XLPE, Fluoropolymer and Low Smoke & fume Zero Halogen.

BASEC PCR

  • PCR-043

    Scope:
    The design, manufacture and supply of the following cable types and products: Flexible Cables and Cords, Instrumentation and Control Cables, Power Cables rated at up to 600/1000V, using the following Insulation and Sheathing Materials: PVC, PE, TPE, XLPE, Fluoropolymer and Low Smoke & Fume Zero Halogen.