Jiangsu Hengtong Power Cable Co., Ltd Visit Website

Jiangsu Hengtong Power Cable Co., Ltd
No. 88 Hengtong Road,
Qidu Town,
Wujiang District,
Suzhou,
215234,
Jiangsu Province,
China

Telephone:
0086 512 63801403

Products (Filtered of )

Filters (1) Edit filter

  • BS EN 50525-2-31:2011
    View Certificate PDF 648KB

    Table Number:
    Table 4.1

    Schedule:
    251/001/001

    Approved Range:
    Single core non-sheathed cables with thermoplastic PVC insulation

    Detail:
    Single core ranges: 1.5sqmm to 1000sqmm are circular stranded conductors

  • BS 5467:2016 Incorporating Corrigendum No. 1
    View Certificate PDF 562KB

    Table Number:
    Table 4, Table 7, Table 5, Table 6

    Schedule:
    251/001/002

    Approved Range:
    Armoured power cables with PVC sheathing

    Detail:
    2 to 4 core ranges: 1.5sqmm to 120sqmm are circular stranded conductors 25sqmm to 400sqmm are shaped stranded conductors

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2
    View Certificate PDF 561KB

    Table Number:
    Table 4, Table 7, Table 5, Table 6

    Schedule:
    251/001/003

    Approved Range:
    Armoured power cables with LSHF sheathing

    Detail:
    2 to 4 core ranges: 1.5sqmm to 120sqmm are circular stranded conductors 25sqmm to 400sqmm are shaped stranded conductors

  • BS EN 50525-3-41:2011
    View Certificate PDF 561KB

    Table Number:
    Table 4.1

    Schedule:
    251/001/004

    Approved Range:
    Single core non-sheathed cables with LSHF crosslinked insulation

    Detail:
    N/A

  • BS 8592:2016
    View Certificate PDF 620KB

    Table Number:
    Table 2

    Schedule:
    251/001/005

    Approved Range:
    Single core fire resistant cables

    Detail:
    N/A

  • BS 7846:2015
    View Certificate PDF 819KB

    Table Number:
    Table 4, Table 5, Table 6

    Schedule:
    251/001/007

    Approved Range:
    Armoured fire resistant power cables

    Detail:
    Resistance to Fire Categories F120

  • BS 7889:2012
    View Certificate PDF 446KB

    Table Number:
    Table 2

    Schedule:
    251/001/008

    Approved Range:
    Non-armoured power cables with PVC sheathing

    Detail:
    600/1000V BS 7889 CU/XLPE/PVC core×nominal area H year.

BASEC PCR

  • PCR-283
    View Certificate PDF 159KB

    Scope:
    Design and manufacture of Low Voltage Cables.

CPR Classification Reports

  • BS 6724 Power Cable, DC 1.5KV&AC3KV, Single Core, 240sqmm

    Report No. T1CPRT4060-2

    Issue Date: 24th April 2023

  • BS 6724 Power Cable, DC 1.5KV&AC3KV, Single Core, 240sqmm

    Report No. T1CPRT4060-1

    Issue Date: 24th April 2023