Huizhou Jinlongyu Cable Industry Development Co., Ltd. Visit Website

Huizhou Jinlongyu Cable Industry Development Co., Ltd.
Maidong,
Jimadi Village,
Luoyang Town,
Boluo County,
Huizhou City,
516100,
Guangdong,
P.R. China

Telephone:
+86 755 84271980

Products (Filtered of )

Filters (1) Edit filter

  • BS EN 50525-2-31:2011
    View Certificate PDF 829KB

    Table Number:
    Table 4.1, Table 4.2

    Schedule:
    202/002/001

    Approved Range:
    Single core non-sheathed cables with thermoplastic PVC insulation

    Detail:
    These cables conform to BS EN 50525-2-31 and, by reference, conform to the appropriate requirements of BS EN 60228 and BS EN 60332-1-2. These cables have a rated voltage of 450/750V.

  • BS EN 50525-3-41:2011
    View Certificate PDF 808KB

    Table Number:
    Table 4.1, Table 4.2

    Schedule:
    202/002/002

    Approved Range:
    Single core non-sheathed cables with LSHF crosslinked insulation

    Detail:
    These cables conform to BS EN 50525-3-41 and, by reference, conform to the appropriate requirements of: BS EN 60228, BS EN 60332-1-2, BS EN 61034-2, BS EN 60754-1, BS EN 60754-2 and BS EN 60684-2 specifications. These cables have rated voltages of 450/750 V for Clause 4.1/Table B.1 & Clause 4.2/Table B.2 .

  • BS 5467:2016 Incorporating Corrigendum No. 1
    View Certificate PDF 871KB

    Table Number:
    Table 4, Table 9, Table 6, Table 5, Table 7

    Schedule:
    202/002/003

    Approved Range:
    Armoured power cables with PVC sheathing

    Detail:
    2-4 cores: 50sqmm-400sqmm are shaped stranded conductors. The rest are circular stranded conductors. Any core colour sequence meeting regulatory requirements permitted. These cables conform to BS 5467 and, by reference, conform to appropriate requirements of BS EN 60228 and BS EN 60332-1-2. These cables have a rated voltage of 600/1000V.

  • BS 6004:2012
    View Certificate PDF 692KB

    Table Number:
    Table 3, Table 4

    Schedule:
    202/002/004

    Approved Range:
    PVC insulated and sheathed cables

    Detail:
    N/A

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2
    View Certificate PDF 589KB

    Table Number:
    Table 4, Table 9, Table 6, Table 5, Table 7, Table 8

    Schedule:
    202/002/005

    Approved Range:
    Armoured power cables with LSHF sheathing

    Detail:
    2-4 cores: 50sqmm-400sqmm are shaped stranded conductors. The rest are circular stranded conductors. Any core colour sequence meeting regulatory requirements permitted. These cables conform to BS 6724 and, by reference, conform to appropriate requirements of BS EN 60228, BS EN 60332-1-2, BS EN 60332-3-24, BS EN 61034-2 and BS EN 60754-1. These cables have a rated voltage of 600/1000V.

  • BS 7846:2015
    View Certificate PDF 914KB

    Table Number:
    Table 4, Table 8, Table 6, Table 5, Table 7

    Schedule:
    202/002/006

    Approved Range:
    Armoured fire resistant power cables

    Detail:
    2-4 cores: 50sqmm-400sqmm are shaped stranded conductors. The rest are circular stranded conductors. Any core colour sequence meeting regulatory requirements permitted. Resistance to Fire Category F2. Tested bend radius 8D. These cables conform to BS 7846 and, by reference, conform to the appropriate requirements of: BS EN 60228, BS EN 60332-1-2, BS EN 60332-3-24, BS EN 61034-2, BS EN 60754-1, and BS 6387 C, W & Z, cables of diameter not exceeding 20mm; cables of diameter exceeding 20mm subjected to the additional requirements of BS 7846 Annex I. These cables have a rated voltage of 600/1000 V.

  • BS 8592:2016
    View Certificate PDF 828KB

    Table Number:
    Table 2

    Schedule:
    202/002/007

    Approved Range:
    Single core fire resistant cables

    Detail:
    These cables conform to BS 8592, and by reference, conform to the appropriate requirements of: BS EN 60228, BS EN 60332-1-2, BS EN 61034-2, BS EN 60754-1 and IEC 60331-3. Additionally tested to BS 6387 C, W & Z, BS EN 50200 PH120 (120 mins).

  • BS 6231:2006 Incorporating Corrigendum No.1
    View Certificate PDF 690KB

    Table Number:
    Table 1

    Schedule:
    202/002/008

    Approved Range:
    Single core non-sheathed cables with thermoplastic PVC insulation

    Detail:
    N/A

  • BS 6231:2006 Incorporating Corrigendum No.1
    View Certificate PDF 828KB

    Table Number:
    Table 2

    Schedule:
    202/002/009

    Approved Range:
    Single core non-sheathed cables with thermoplastic PVC insulation

    Detail:
    These cables conform to BS 6231 and, by reference, conform to the appropriate requirements of BS EN 60228 and BS EN 60332-1-2. These cables have a rated voltage of 600/1000V.

  • BS 7846:2015
    View Certificate PDF 912KB

    Table Number:
    Table 4, Table 5, Table 6

    Schedule:
    202/002/010

    Approved Range:
    Armoured fire resistant power cables

    Detail:
    2-3 cores: 10sqmm-35sqmm are circular stranded conductors only, and 50sqmm-400sqmm are shaped stranded conductors only. 4-cores: 4sqmm-35sqmm are circular stranded conductors only and 50sqmm-400sqmm are shaped stranded conductors only. Any core colour sequence meeting regulatory requirements permitted. Resistance to Fire -Category F120. These cables conform to BS 7846 and, by reference, conform to the appropriate requirements of BS EN 60228, BS EN 60332-1-2, BS EN 60332-3-24, BS EN 61034-2, BS EN 60754-1, BS 8491 and BS 6387 C, W & Z specifications. These cables have a rated voltage of 600/1000V.

  • BS 8573:2012
    View Certificate PDF 861KB

    Table Number:
    Table 2

    Schedule:
    202/002/011

    Approved Range:
    Non-armoured power cables with LSHF sheathing

    Detail:
    These cables conform to BS 8573, and by reference, conform to the appropriate requirements of: BS EN 60228, BS EN 60332-1-2, BS EN 61034-2, BS EN 60754-1, and BS EN 60332-3-24. These cables have a rated voltage of 600/1000 V.

  • BS 7889:2012
    View Certificate PDF 829KB

    Table Number:
    Table 2, Table 3, Table 4, Table 5

    Schedule:
    202/002/012

    Approved Range:
    Non-armoured power cables with PVC sheathing

    Detail:
    Any core colour sequence meeting regulatory requirements. These cables conform to BS 7889 and, by reference, conform to the appropriate requirements of BS EN 60228 and BS EN 60332-1-2. These cables have a rated voltage of 600/1000V.

  • IEC 60502-1:2021 Edition 3
    View Certificate PDF 829KB

    Table Number:
    Table N/A

    Schedule:
    202/002/013

    Approved Range:
    Low voltage power cables up to 1kV

    Detail:
    These un-armoured cables conform to IEC 60502-1, and by reference, conform to the appropriate requirements of : IEC 60228, IEC 60332-1-2, IEC 61034-2, IEC 60754-1, IEC 60754-2, IEC 60684-2 and IEC 60332-3-24 Cat C. These cables have a rated voltage of 600/1000 V.

  • IEC 60502-2:2014
    View Certificate PDF 902KB

    Table Number:
    Table N/A

    Schedule:
    202/002/014

    Approved Range:
    Medium voltage power cables up to 36 kV with PVC sheathing

    Detail:
    Circular stranded plain copper or aluminium conductors (Class 2), extruded cross-linkable semi-conducting conductor screen, extruded cross-linkable polyethylene (XLPE) insulation, extruded cross-linkable semi-conducting bonded or strippable insulation screen, copper tape and/or copper wire screened, extruded polyvinyl chloride (PVC/ST2) separation sheath, aluminium wire or aluminium tape armour for single core cables and galvanized steel wire or galvanized steel tape armour for multi-core cables, extruded polyvinyl chloride (PVC/ST2) oversheath. The cables' design, materials, and testing conform to IEC 60502-2, IEC 60228. The cables have the following rated voltage: 3.8/6.6 (7.2) kV; 6.35/11 (12) kV; 8.7/15 (17.5) kV; 12.7/22 (24) kV and 19/33 (36) kV

  • IEC 60502-2:2014
    View Certificate PDF 915KB

    Table Number:
    Table N/A

    Schedule:
    202/002/015

    Approved Range:
    Medium voltage power cables up to 36 kV with LSHF sheathing

    Detail:
    Circular stranded plain copper or aluminium conductors (Class 2), extruded cross-linkable semi-conducting conductor screen, extruded cross-linkable polyethylene (XLPE) insulation, extruded cross-linkable semi-conducting bonded or strippable insulation screen, copper tape and/or copper wire screened, extruded low smoke non-halogen (LSNH/ST8) separation sheath, aluminium wire or aluminium tape armour for single core cables and galvanized steel wire or galvanized steel tape armour for multi-core cables, extruded low smoke non-halogen (LSNH/ST8) over sheath. The cables' design, materials, and testing conform to IEC 60502-2 (Generally), IEC 60228, IEC 60502-1 (for LSHF/ST8 material), IEC 60332-1-2, IEC 60332-3-24, IEC 61034-2 and IEC 60754-1, IEC 60754-2, IEC 60684-2. The cables have the following rated voltage: 3.8/6.6 (7.2) kV; 6.35/11 (12) kV; 8.7/15 (17.5) kV; 12.7/22 (24) kV and 19/33 (36) kV

Quality (ISO 9001)

  • CS1-246/002
    View Certificate PDF 168KB

    Scope:
    The design, manufacture and supply of the following cable types: Plastic insulated screened and un-screened control cables. PVC insulated un-sheathed cable of rated voltage 450/750V and below. PVC insulated and PVC sheathed cables. PVC insulated and PVC sheathed flexible cables. Armoured and non-armoured power Cable of rated voltage 1KV and 3KV. Pre-fabricated branch cable. LSHF flame retardant power cable. Fire resistant power cable. Flame retardant power cable. Compounding of polymers. and Medium voltage power cables up to 36 kV with XLPE insulation and LSHF sheathing. Medium voltage power cables up to 36 kV with XLPE insulation and PVC sheathing.

BASEC PCR

  • PCR-246/002
    View Certificate PDF 157KB

    Scope:
    The design, manufacture and supply of the following cable types: Single core non-sheathed cables with thermoplastic PVC insulation of rated voltage 450/750V. Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke of rated voltage 450/750V. PVC insulated and PVC sheathed cables for voltage 300/500V. Thermosetting insulated, armoured cables for voltages of 600/1000V with PVC oversheath or low emission of smoke and corrosive gases oversheath. Thermosetting insulated, armoured, fire resistant cables of rated voltage 600/1000V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Fire-resistant, single core non-sheathed cables with halogen-free crosslinked insulation of rate voltage 450/750V and Medium voltage power cables up to 36 kV with XLPE insulation and LSHF sheathing. Medium voltage power cables up to 36 kV with XLPE insulation and PVC sheathing.