HES HACILAR ELEKTRIK SANAYI VE TICARET A.S. Visit Website

Licence Number:
227

Origin Mark:
HES

HES HACILAR ELEKTRIK SANAYI VE TICARET A.S.
Erciyes Mah. Hes Cd. No:22
38210 Hacilar / KAYSERI
TURKEY

Products (Filtered of )

Filters (1) Edit filter

  • BS EN 50525-3-41:2011
    View Certificate PDF 266KB

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    227/001/001

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.5sqmm to 240sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - EI5

  • BS EN 50525-3-41:2011
    View Certificate PDF 265KB

    Table Number:
    Clause 4.2 Table B.2

    Schedule:
    227/001/002

    Approved Range:
    1.5sqmm to 240sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - EI5

  • BS EN 50525-3-41:2011
    View Certificate PDF 265KB

    Table Number:
    Clause 4.3 Table B.3

    Schedule:
    227/001/003

    Approved Range:
    0.5sqmm to 1sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. Insulation - EI5

  • BS EN 50525-3-41:2011
    View Certificate PDF 265KB

    Table Number:
    Clause 4.4 Table B.4

    Schedule:
    227/001/004

    Approved Range:
    0.5sqmm to 1sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - EI5

  • BS 6004:2012
    View Certificate PDF 265KB

    Table Number:
    Table 3

    Schedule:
    227/001/005

    Approved Range:
    1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Single-core to flat 3-core inclusive. Class 1 conductor. 4sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. 4sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat twin to flat 3-core inclusive. Class 2 conductor. Sheath Type 6. Insulation - TI1.

  • BS 6004:2012
    View Certificate PDF 265KB

    Table Number:
    Table 4

    Schedule:
    227/001/006

    Approved Range:
    1sqmm to 1.5sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat twin to flat 3-core inclusive. Class 1 conductor. 4sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat twin to flat 3-core inclusive. Class 2 conductor. Sheath - Type 6. Insulation - TI1.

  • BS 6004:2012
    View Certificate PDF 265KB

    Table Number:
    Table 5

    Schedule:
    227/001/007

    Approved Range:
    1.5sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat twin without CPC. Class 2 conductor. 1.5sqmm nominal cross-sectional area of conductor. Single-core with CPC. Class 2 conductor. 1.5sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat twin with CPC. Class 2 conductor. Sheath - Type 6. Insulation - TI1.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    227/001/008

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.5sqmm to 240sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - TI1.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.2 Table B.2

    Schedule:
    227/001/009

    Approved Range:
    1.5sqmm to 240sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - TI1

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.3 Table B.3

    Schedule:
    227/001/010

    Approved Range:
    0.5sqmm to 1sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 0.5sqmm to 1sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - TI1

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.4 Table B.4

    Schedule:
    227/001/011

    Approved Range:
    0.5sqmm to 1sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - TI1

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 5.1 Table B.1

    Schedule:
    227/001/012

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.5sqmm to 35 sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - TI3.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 5.2 Table B.2

    Schedule:
    227/001/013

    Approved Range:
    1.5sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - TI3

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 5.3 Table B.3

    Schedule:
    227/001/014

    Approved Range:
    0.5sqmm to 1sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 0.5sqmm to 1sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - TI3

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 5.4 Table B.4

    Schedule:
    227/001/015

    Approved Range:
    0.5sqmm to 1sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - TI3

  • BS 6004:2012

    Table Number:
    Table 6

    Schedule:
    227/001/016

    Approved Range:
    0.75sqmm & 1sqmm nominal cross-sectional area of conductors inclusive. Flat Twin. Class 5 conductor. 0.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. Circular 2-core. Class 5 conductor. 0.75sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 2-core to 5-core. Class 5 conductor. Sheath - Type 10. Insulation - TI4.

  • BS 7211:2012

    Table Number:
    Table 3

    Schedule:
    227/001/017

    Approved Range:
    25sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Sheath - LTS4. Insulation - GP8.

  • BS 7211:2012

    Table Number:
    Table 4

    Schedule:
    227/001/018

    Approved Range:
    25sqmm nominal cross-sectional area of conductors inclusive. 5-core. Class 2 conductor. Sheath - LTS4. Insulation - GP8.

  • BS 7211:2012

    Table Number:
    Table 5

    Schedule:
    227/001/019

    Approved Range:
    1sqmm & 1.5sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. Sheath - LTS2 . Insulation - GP8.

  • BS 7211:2012

    Table Number:
    Table 5

    Schedule:
    227/001/020

    Approved Range:
    1sqmm to 25sqmm nominal cross-sectional area of conductors inclusive. Flat twin to 3-core inclusive. Class 2 conductor. 1sqmm to 16 sqmm nominal cross-sectional area of conductors inclusive. Flat twin. Class 2 conductor. 4sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat 3-core. Class 2 conductor. Sheath - LTS2. Insulation -. GP8

BASEC PCR