Walsin LIHWA Corporation

Licence Number:
221

Origin Mark:
WALSIN LIHWA

Walsin LIHWA Corporation
Plant 1 No. 397, Xinshu Rd.,
Xinzhuang Dist.,
New Taipei City 24262
Taiwan, ROC

Product Schedule

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    221/001/001

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.5sqmm to 500 sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - TI1

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.2 Table B.2

    Schedule:
    221/001/002

    Approved Range:
    1.5sqmm to 240sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - TI1

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.3 Table B.3

    Schedule:
    221/001/003

    Approved Range:
    0.5sqmm to 1sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 0.5sqmm to 1sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - TI1

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.4 Table B.4

    Schedule:
    221/001/004

    Approved Range:
    0.5sqmm to 1sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - TI1

  • BS 6004:2012

    Table Number:
    Table 3

    Schedule:
    221/001/005

    Approved Range:
    1.0sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 4sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - TI1 .Sheath - Type 6.

  • BS 7889:2012

    Table Number:
    Tables 2

    Schedule:
    221/001/006

    Approved Range:
    1.5sqmm to 1000sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Sheath - Type 9. Insulation - GP8.

  • BS 7889:2012

    Table Number:
    Tables 3, 4 and 5

    Schedule:
    221/001/007

    Approved Range:
    1.5sqmm to 120sqmm nominal cross-sectional area of conductors inclusive. Two-core to 4-core inclusive. Class 2 conductor. Sheath - Type 9. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No. 1:2016

    Table Number:
    Table 4

    Schedule:
    221/001/008

    Approved Range:
    50sqmm to 1000sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Sheath - Type 9. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No. 1:2016

    Table Number:
    Tables 5, 6 and 7

    Schedule:
    221/001/009

    Approved Range:
    1.5sqmm to 25sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. Class 2 circular conductor. 35sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. Class 2 shaped conductor. Sheath - Type 9. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No. 1:2016

    Table Number:
    Table 9

    Schedule:
    221/001/010

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 37-core inclusive. Class 2 circular conductor. Sheath - Type 9. Insulation - GP8.

BASEC PCR