Draka UK Ltd Visit Website

Licence Number:
189

Draka UK Ltd
Chickenhall Lane
Eastleigh, Hampshire
United Kingdom

Telephone:
01332 345431

Product Schedule

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    189/001/061

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Non HAR colours; yellow, green and combinations of other colours. Insulation - EI5.

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    189/001/062

    Approved Range:
    1.5sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - EI5.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    189/001/063

    Approved Range:
    1.5sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Non HAR colours; yellow, green and combinations of other colours. Insulation - TI1.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    189/001/064

    Approved Range:
    1.5sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - TI1.

  • BS 7889:2012

    Table Number:
    Table 2

    Schedule:
    189/001/065

    Approved Range:
    1.5sqmm to 95sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Sheath - Type 9. Insulation - GP8.

  • BS 7629-1:2015

    Table Number:
    Table 2

    Schedule:
    189/001/066

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 2-core to 4-core inclusive. STANDARD 60. Additionally tested to BS 6387:2013 Categories C, W & Z. Sheath - LTS3. Insulation - EI2.

  • BS 7629-1:2015

    Table Number:
    Table 2

    Schedule:
    189/001/067

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 2-core to 4-core inclusive. ENHANCED 120. Additionally tested to BS 6387:2013 Categories C, W & Z. Sheath - LTS3. Insulation - EI2.

  • BS 7629-1:2015

    Table Number:
    Table 2

    Schedule:
    189/001/068

    Approved Range:
    1.0sqmm nominal cross-sectional area of conductors inclusive. 2-core. 1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 2-core to 4-core inclusive. STANDARD 60. Additionally tested to BS 6387:2013 Categories C, W & Z. Sheath - LTS3. Insulation - EI5.

  • BS 7846:2015

    Table Number:
    Tables 4, 5, 6 & 7

    Schedule:
    189/001/069

    Approved Range:
    1.5sqmm to 70sqmm nominal cross-sectional area of conductors inclusive. Two core to four core inclusive. Sheath - LTS1. Insulation - GP8. 1.5sqmm to 10 sqmm nominal cross-sectional area of conductors inclusive. Five core. Resistance to fire - Category F2. Sheath - LTS1. Insulation - GP8.

  • BS 7846:2015

    Table Number:
    Table 8

    Schedule:
    189/001/070

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 37-core inclusive. Resistance to fire - Category F2. Sheath - LTS1. Insulation - GP8.

  • BS 7846:2015

    Table Number:
    Table 4, 5, 6 & 7

    Schedule:
    189/001/071

    Approved Range:
    4sqmm to 70sqmm nominal cross-sectional area of conductors inclusive. Two core to three core inclusive. 4sqmm to 50sqmm nominal cross-sectional area of conductors inclusive. Four core. 4sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Five core. Resistance to fire - Category F120. Sheath - LTS1. Insulation - GP8. This approval is based on the use of 1.25mm armour wire for the following cables: Table 4 two core 4, 6 & 10sqmm, Table 5 three core 4 & 6sqmm, Table 6 four core 4sqmm and Table 7 five core 4sqmm.

  • BS 5467:2016 Incorporating Corrigendum No. 1

    Table Number:
    Table 9

    Schedule:
    189/001/072

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 37-core inclusive. Sheath - Type 9. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No. 1

    Table Number:
    Tables 5, 6, 7 & 8

    Schedule:
    189/001/073

    Approved Range:
    1.5sqmm to 70sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. 1.5qmm to 10sqmm nominal cross-sectional area of conductors inclusive. Five-core. Sheath - Type 9. Insulation - GP8.

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2

    Table Number:
    Tables 5, 6, 7 & 8

    Schedule:
    189/001/074

    Approved Range:
    1.5sqmm to 70sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. 1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Five-core. Sheath - LTS1. Insulation - GP8.

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2

    Table Number:
    Table 9

    Schedule:
    189/001/075

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 48-core inclusive. Sheath - LTS1. Insulation - GP8.

  • BS 7629-1:2015

    Table Number:
    Table 2

    Schedule:
    189/001/076

    Approved Range:
    1.5sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. 2-core. ENHANCED 120. Additionally tested to BS 6387:2013 Categories C, W & Z. Sheath - LTS3. Insulation - EI5.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    189/002/035

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.5sqmm to 25sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Colours: black, blue, brown, grey, orange, pink, red, turquoise, violet, white and combination green/yellow. Insulation - TI1.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    189/002/036

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.5sqmm to 25sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Solid and stranded conductor. Colours: green, yellow and combinations of other colours. Insulation - TI1.

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    189/002/037

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.5sqmm to 25sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - EI5.

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    189/002/038

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.5sqmm to 25sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - EI5.

  • BS 7211:2012

    Table Number:
    Table 5

    Schedule:
    189/002/039

    Approved Range:
    1sqmm to 1.5sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat twin to flat 3-core inclusive. Class 1 conductor. 1sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat twin. Class 2 conductor. Sheath - LTS2. Insulation - GP8.

  • BS 6004:2012

    Table Number:
    Table 3

    Schedule:
    189/002/040

    Approved Range:
    1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Single core to flat twin inclusive. Class 1 conductor. 4sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Single core. Class 2 conductor. 4sqmm nominal cross-sectional area of conductor. Flat twin. Class 2 conductor. Sheath - Type 6. Insulation - TI1.

  • BS 6004:2012

    Table Number:
    Table 4

    Schedule:
    189/002/041

    Approved Range:
    1sqmm to 1.5sqmm nominal cross-sectional area of conductors inclusive. Single core & flat 3-core only. Class 1 conductor. 1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat twin. Class 1 conductor. 4sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat twin. Class 2 conductor. Sheath - Type 6. Insulation - TI1.

  • BS 6004:2012

    Table Number:
    Table 5

    Schedule:
    189/002/042

    Approved Range:
    1.5sqmm nominal cross-sectional area of conductor. Single-core. Class 2 conductor, with CPC. 1.5sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat twin. Class 2 conductor, with CPC. Sheath - Type 6. Insulation - TI1.

  • BS 5467:2016 Incorporating Corrigendum No. 1

    Table Number:
    Tables 5, 6, 7 & 8

    Schedule:
    189/002/043

    Approved Range:
    1.5sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. 1.5sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Five-core. Sheath - Type 9. Insulation - GP8.

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2

    Table Number:
    Tables 5, 6, 7 & 8

    Schedule:
    189/002/044

    Approved Range:
    1.5sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. 1.5sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Five-core. Sheath - LTS1. Insulation - GP8.

  • BS 7889:2012

    Table Number:
    Table 2

    Schedule:
    189/003/022

    Approved Range:
    120sqmm to 1000sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Sheath - Type 9. Insulation - GP8.

  • BS 7846:2015

    Table Number:
    Tables 4, 5 and 6

    Schedule:
    189/003/023

    Approved Range:
    50sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Two core to four core inclusive. Resistance to fire - Category F2. Sheath - LTS1. Insulation - GP8.

  • BS 7846:2015

    Table Number:
    Table 4, 5 and 6

    Schedule:
    189/003/024

    Approved Range:
    95sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Twio core to three core inclusive. 70sqmm to 400 sqmm nominal cross-sectional area of conductors inclusive. Four core. Resistance to fire - Category F120. Sheath - LTS1. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No. 1

    Table Number:
    Table 4

    Schedule:
    189/003/025

    Approved Range:
    120sqmm to 1000sqmm nominal cross-sectional areas of conductor inclusive. Single-core. Sheath - Type 9. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No. 1

    Table Number:
    Tables 5, 6 and 7

    Schedule:
    189/003/026

    Approved Range:
    70sqmm to 400sqmm nominal cross-sectional areas of conductor inclusive. Two-core to four-core inclusive. Sheath - Type 9. Insulation - GP8.

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2

    Table Number:
    Table 4

    Schedule:
    189/003/027

    Approved Range:
    95sqmm to 1000sqmm nominal cross-sectional areas of conductor inclusive. Single-core. Sheath - LTS1. Insulation - GP8.

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2

    Table Number:
    Tables 5, 6 and 7

    Schedule:
    189/003/028

    Approved Range:
    70sqmm to 400sqmm nominal cross-sectional areas of conductor inclusive. Two-core to four-core inclusive. Sheath - LTS1. Insulation - GP8.

Quality (ISO 9001)

CPR