Product Schedule

  • BS 6724:1997 and A3:2008

    Table Number:
    Table 4

    Schedule:
    178/001/043

    Approved Range:
    50sqmm to 800sqmm nominal cross-sectional area of conductors inclusive. Single-core. Sheath - LTS1. Insulation - GP8.

  • BS 6724:1997 and A3:2008

    Table Number:
    Tables 6, 8 and 10

    Schedule:
    178/001/044

    Approved Range:
    1.5sqmm to 95sqmm nominal cross-sectional area of conductors inclusive. Two-core. 1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Three-core to four-core inclusive. Sheath - LTS1. Insulation - GP8.

  • BS 7835:2007 Incorporating Corrigendum No.1

    Schedule:
    178/001/045

    Approved Range:
    70sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Single-core. 70sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. 3-core. Stranded circular copper or aluminium class 2 conductors. XLPE insulation. Bonded or strippable semi-conducting insulation screen. Copper tape and/or copper wire screened. Low smoke, zero halogen, extruded inner sheath. Aluminium round wire armoured (single-core cables). Galvanised steel round wire armoured (3-core cables).LTS-1 low smoke, zero halogen, extruded outer sheath.

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    178/001/046

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.5sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - EI5.

  • IEC 60502-2:2014

    Schedule:
    178/001/047

    Approved Range:
    95sqmm to 630sqmm nominal cross-sectional area of conductor inclusive. Single-core. XLPE Insulation. Bonded or strippable semi-conducting insulation screen. Copper wire and/or tape screen. ST8 low smoke, zero halogen, extruded outer sheath. Voltage ratings: 3,6/6(7,2)kV, 6/10(12)kV, 8.7/15(17.5)kV. Zero Halogen to IEC 60754 1&2. Low smoke to IEC 61034.

  • IEC 60502-2:2014

    Schedule:
    178/001/048

    Approved Range:
    Up to 400sqmm nominal cross-sectional area of conductors inclusive. 3-core. Up to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. XLPE Insulation. Bonded or strippable semi-conducting insulation screen. Copper tape and/or copper wire screened. Low smoke, zero halogen, extruded inner sheath. Galvanised steel round wire armoured (3-core cables). Aluminium round wire armoured (single-core cables). ST8 low smoke, zero halogen, extruded outer sheath. Voltage ratings: 3,6/6(7,2)kV, 6/10(12)kV and 8.7/15(17.5)kV. Generally to IEC 60502-2 and including IEC 60332-3.24, IEC 61034 and IEC 60754 specifications.

  • IEC 60502-2:2014

    Schedule:
    178/001/049

    Approved Range:
    Up to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. XLPE Insulation. Bonded or strippable semi-conducting insulation screen. Copper tape and/or copper wire screened. Low smoke, zero halogen, extruded inner sheath. ST8 low smoke, zero halogen, extruded outer sheath. Aluminium/MDPE laminated sheathed. Water blocked and non-water blocked types. Voltage ratings: 3,6/6(7,2)kV, 6/10(12)kV, 8.7/15(17.5)kV, 12/20(24)kV and 18/30(36)kV.

  • IEC 60502-2:2014

    Schedule:
    178/001/050

    Approved Range:
    Up to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. XLPE Insulation. Bonded or strippable semi-conducting insulation screen. Copper tape and/or copper wire screened. Low smoke, zero halogen, extruded inner sheath. ST8 low smoke, zero halogen, extruded outer sheath. Lead sheathed. Water blocked and non-water blocked types. Voltage ratings: 3,6/6(7,2)kV, 6/10(12)kV, 8.7/15(17.5)kV, 12/20(24)kV and 18/30(36)kV.

  • BS 8573:2012

    Table Number:
    Tables 2, 3, 4 and 5

    Schedule:
    178/001/051

    Approved Range:
    1.5sqmm to 800sqmm nominal cross-sectional area of conductors inclusive. Single-core. 1.5sqmm to 120sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. Sheath - LTS4. Insulation - GP8.

  • IEC 60502-1 Edition 2.1:2009

    Schedule:
    178/001/052

    Approved Range:
    1.5sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. 1.5sqmm to 300sqmm nominal cross-sectional area of conductors inclusive. 2-core. 1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. 3-core to 4-core inclusive. IEC 60331-21:1999. BS 6387:2013 Categories C, W & Z. Sheath - ST8. Insulation - XLPE.

  • IEC 60502-1 Edition 2.1:2009

    Schedule:
    178/001/053

    Approved Range:
    1.5sqmm to 800sqmm nominal cross-sectional area of conductors inclusive. Single-core. 1.5sqmm to 300sqmm nominal cross-sectional area of conductors inclusive. 2-core. 1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. 3-core to 4-core inclusive. Sheath - ST8. Insulation - XLPE.

  • BS 7846:2015

    Table Number:
    Tables 4, 5 and 6

    Schedule:
    178/001/054

    Approved Range:
    1.5sqmm to 95sqmm nominal cross-sectional area of conductors inclusive. Two core. 1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Three core to four core inclusive. Resistance to fire - Category F2. Sheath - LTS1. Insulation - GP8.

  • BS 7846:2015

    Table Number:
    Tables 4, 5 and 6

    Schedule:
    178/001/055

    Approved Range:
    6sqmm to 95sqmm nominal cross-sectional area of conductors inclusive. Two core. 6sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Three core to four core inclusive. Resistance to fire - Category F120. Sheath - LTS1. Insulation - GP8.

BASEC PCR

  • PCR-229

    Scope: