Seval Kablo Aydinlatma Cih. Ith. Ih. San. Tic. A.S. Visit Website

Licence Number:
179

Origin Mark:
SEVAL KABLO or SK or 179/001 or SVL or ETS or EMU or HAE

Seval Kablo Aydinlatma Cih. Ith. Ih. San. Tic. A.S.
Haci Eyup Mah. 3119
Sk. No:5 Ucler
20195 Denizli
Turkey

Telephone:
00902583714248

Product Schedule

  • BS 5467:1997 and A3:2008

    Table Number:
    Table 18

    Schedule:
    179/001/056

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 19-core inclusive. Sheath - Type 9. Insulation - GP8.

  • BS 6724:1997 and A3:2008

    Table Number:
    Table 18

    Schedule:
    179/001/057

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 19-core inclusive. Sheath - LTS1. Insulation - GP8.

  • BS 7211:2012

    Table Number:
    Table 5

    Schedule:
    179/001/058

    Approved Range:
    1sqmm to 1.5sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. 2-core to 3-core inclusive. Class 1 conductor. 1sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. 2-core to 3-core inclusive. Class 2 conductor. Sheath - LTS2. Insulation - GP8.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    179/001/059

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.5sqmm to 240sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - TI1.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.2 Table B.2

    Schedule:
    179/001/060

    Approved Range:
    1.5sqmm to 240sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - TI1.

  • BS EN 50525-2-11:2011

    Table Number:
    Clause 4.2 Table B.2

    Schedule:
    179/001/061

    Approved Range:
    0.75sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 2-core to 5-core inclusive. Circular cables. 0.75sqmm to 1.5sqmm nominal cross-sectional area of conductors inclusive. Twin-core. Flat cables. Class 5 conductor. Sheath - TM2. Insulation - TI2.

  • BS 6004:2012

    Table Number:
    Table 3

    Schedule:
    179/001/062

    Approved Range:
    1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 4sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Sheath - Type 6. Insulation - TI1.

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    179/001/063

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.5sqmm to 240sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - EI5

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.2 Table B.2

    Schedule:
    179/001/064

    Approved Range:
    1.5sqmm to 240sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - EI5.

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.4 Table B.4

    Schedule:
    179/001/065

    Approved Range:
    0.5sqmm to 1sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - EI5

  • BS 6004:2012

    Table Number:
    Table 5

    Schedule:
    179/001/066

    Approved Range:
    1.5sqmm nominal cross-sectional area of conductor. Single-core. Class 2 conductor, with CPC. 1.5sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat twin. Class 2 conductor, with & without CPC. Sheath - Type 6. Insulation - TI1.

  • BS 6004:2012

    Table Number:
    Table 4

    Schedule:
    179/001/067

    Approved Range:
    1sqmm to 1.5sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat twin to flat 3-core inclusive. Class 1 conductor. 4sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat twin to flat 3-core inclusive. Class 2 conductor. Sheath - Type 6. Insulation - TI1.

  • BS 6004:2012

    Table Number:
    Table 6

    Schedule:
    179/001/068

    Approved Range:
    0.75sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 2-core to 5-core inclusive. Class 5 conductor. Sheath - Type 10. Insulation - TI4.

  • BS 7211:2012

    Table Number:
    Table 3

    Schedule:
    179/001/069

    Approved Range:
    1sqmm to 6sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Sheath - LTS4. Insulation - GP8.

  • BS EN 50525-2-11:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    179/001/070

    Approved Range:
    0.5sqmm to 0.75sqmm nominal cross-sectional area of conductors inclusive. 2-core to 4-core inclusive. Class 5 conductor. Circular cables. 0.5sqmm to 0.75sqmm nominal cross-sectional area of conductors inclusive. 2-core. Class 5 conductor. Flat cables. Sheath -TM2. Insulation - TI2.

  • BS 5467:1997 and A3:2008

    Table Number:
    Tables 6, 8, 10 and 13

    Schedule:
    179/001/071

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. 1.5sqmm to 70sqmm nominal cross-sectional area of conductors inclusive. Five-core. Sheath - Type 9. Insulation - GP8.

  • BS 6724:1997 and A3:2008

    Table Number:
    Tables 6, 8, 10 and 13

    Schedule:
    179/001/072

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. 1.5sqmm to 70sqmm nominal cross-sectional area of conductors inclusive. Five-core. Sheath - LTS1. Insulation - GP8.

  • I.S. 201-4:2013

    Table Number:
    Table 1

    Schedule:
    179/001/073

    Approved Range:
    1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Twin flat with an insulated earth conductor. Class 1 conductor. 1sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Twin flat with an insulated earth conductor. Class 2 conductor. Sheath - Type 6. Insulation - TI1.

  • I.S. 201-4:2013

    Table Number:
    Table 2 PVC/PVC Flat Twin with insulated earth

    Schedule:
    179/001/074

    Approved Range:
    6sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat twin with insulated earth. Class 5 conductor. Sheath - Type 6. Insulation - TI1.

  • I.S. 201-4:2013

    Table Number:
    Table 5

    Schedule:
    179/001/075

    Approved Range:
    1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 & Class 2 conductor. Sheath - Type 6. Insulation - TI1.

BASEC PCR

  • PCR-228

    Scope:
    The design, manufacture and supply of the following cable types: Low Voltage Armoured and Unarmoured Electric Power Cables and Wires. The manufacture of: Various PVC Compounds.