Dongguan Minxing Cables Co. Ltd. Visit Website

Licence Number:
165

Origin Mark:
DONGGUAN MINXING or MXC or STRATA 02 or BASEC 165 or HILLY02

Dongguan Minxing Cables Co. Ltd.
Hongying Industrial Park
Longping Road, Fenggang Town
Dongguan City, Guangdong Province
China

Telephone:
00 86 769 8207 3295

Product Schedule

  • BS 6004:2000 Incorporating Amendment Nos. 1 and 2

    Table Number:
    Table 4a

    Schedule:
    165/001/036

    Approved Range:
    1.5sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Single-core. Insulation - TI1.

  • BS 6004:2000 Incorporating Amendment Nos. 1 and 2

    Table Number:
    Table 8

    Schedule:
    165/001/037

    Approved Range:
    1sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat twin-core to 3-core inclusive. Sheath - Type 6. Insulation - TI1.

  • BS 6004:2012

    Table Number:
    Table 4

    Schedule:
    165/001/038

    Approved Range:
    1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat twin to 3-core inclusive. Class 1 conductor. 4sqmm to 16sqmm nominal cross sectional area of conductors inclusive. Flat twin to 3-core inclusive. Class 2 conductor. Sheath - Type 6. Insulation - TI1.

  • BS 6004:2012

    Table Number:
    Table 5

    Schedule:
    165/001/039

    Approved Range:
    1.5sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat twin. Class 2 conductor. With CPC. Sheath - Type 6. Insulation - TI1.

  • BS 6004:2012

    Table Number:
    Table 3

    Schedule:
    165/001/040

    Approved Range:
    1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 4sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Sheath - Type 6. Insulation - TI1.

  • BS 7889:2012

    Table Number:
    Table 2

    Schedule:
    165/001/041

    Approved Range:
    1.5sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Sheath - Type 9. Insulation - GP8.

  • BS 5467:1997 and A3:2008

    Table Number:
    Table 18

    Schedule:
    165/001/043

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 48-core inclusive. Sheath - Type 9. Insulation - GP8.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    165/001/044

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Class 1 conductor. 1.5sqmm to 500sqmm nominal cross-sectional area of conductors inclusive. Class 2 conductor. Single-core. Insulation - TI1

  • BS 6346:1997 Incorporating Amendment Nos. 1 and 2

    Table Number:
    Table 9 and Table 11

    Schedule:
    165/001/045

    Approved Range:
    1.5sqmm to 300sqmm nominal cross-sectional area of conductors inclusive. 3-core to 4-core inclusive. Sheath - TM1. Insulation - TI1.

  • BS 5467:1997 and A3:2008

    Table Number:
    Tables 8 and 10

    Schedule:
    165/001/046

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. 3-core to 4-core inclusive. Sheath - Type 9. Insulation - GP8.

BASEC PCR

CPR