ATOM KABLO SAN. VE TIC. A.S. Visit Website

Licence Number:
097

Origin Mark:
ATOM KABLO 207/001

Origin Mark:
ATOM KABLO or 097 PX92 or 207/001 or AT-TOP (for BS 6004, table 4 only) or DS CABLES (for BS 5467 only)

ATOM KABLO SAN. VE TIC. A.S.
Akhan Mahallesi
238 Sokak No:4
Denizli
Turkey

Telephone:
+90 258 274 6352

Product Schedule

  • BS 5467:2016 Incorporating Corrigendum No. 1

    Table Number:
    Tables 5, 6, 7 and 8

    Schedule:
    097/001/138

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. 1.5sqmm to 70sqmm nominal cross-sectional are of conductors inclusive. Five-core. Sheath - Type 9. Insulation - GP8.

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2

    Table Number:
    Tables 5, 6, 7 & 8

    Schedule:
    097/001/139

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. 1.5sqmm to 70sqmm nominal cross-sectional area of conductors inclusive. Five-core. Sheath - LTS1. Insulation - GP8.

  • BS 6231:2006 Incorporating Corrigendum No.1

    Table Number:
    Table 2

    Schedule:
    097/001/140

    Approved Range:
    0.5sqmm to 240sqmm nominal cross-sectional area of conductors inclusive. Single-core. Insulation - TI3.

  • BS 5467:2016 Incorporating Corrigendum No. 1

    Table Number:
    Table 9

    Schedule:
    097/001/141

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 37-core inclusive. Sheath - Type 9. Insulation - GP8.

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2

    Table Number:
    Table 9

    Schedule:
    097/001/142

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 37-core inclusive. Sheath - LTS1. Insulation - GP8.

  • BS 6004:2012

    Table Number:
    Table 3

    Schedule:
    097/001/143

    Approved Range:
    1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 4sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. 1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat twin to flat 3-core inclusive. Class 1 conductor. 4sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat twin to flat 3-core inclusive. Sheath - Type 6. Insulation - TI1.

  • BS 6004:2012

    Table Number:
    Table 4

    Schedule:
    097/001/144

    Approved Range:
    1sqmm to 1.5sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat twin to flat 3-core inclusive. Class 1 conductor. 4sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat twin to flat 3-core inclusive. Class 2 conductor. Sheath - Type 6. Insulation - TI1.

  • BS 8436:2011

    Table Number:
    Table 1

    Schedule:
    097/001/145

    Approved Range:
    1.0sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 2-core to 4-core inclusive. Class 2 conductor. Sheath - LTS 3. Insulation - GP8.

  • I.S. 273:1988 Incorporating Amendment No.1:1993 and Amendment No.2:2003

    Table Number:
    Table 37

    Schedule:
    097/001/146

    Approved Range:
    1.0sqmm to 6sqmm nominal cross-sectional area of conductors inclusive. 2-core to 4-core inclusive. Class 2 conductor. Sheath - LTS3. Insulation - GP8.

  • BS EN 50525-3-31:2011

    Table Number:
    Clause 4.1

    Schedule:
    097/001/147

    Approved Range:
    1.5sqmm to 240sqmm nominal cross-sectional area of conductors inclusive. Single-core. Insulation - TI7

  • BS 7211:2012

    Table Number:
    Table 5

    Schedule:
    097/001/148

    Approved Range:
    1sqmm to 1.5sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat twin. Class 2 conductor. 1.sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat 3-core. Class 1 conductor. 4sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat 3-core. Class 2 conductor. Sheath - LTS2. Insulation - GP8.

  • BS 7211:2012

    Table Number:
    Table 5

    Schedule:
    097/001/149

    Approved Range:
    1sqmm to 1.5sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat twin. Class 2 conductor. 1.sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat 3-core. Class 1 conductor. 4sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat 3-core. Class 2 conductor. Sheath - LTS2. Insulation - GP8.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    097/001/150

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.5sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - TI1.

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    097/001/151

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.5sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - EI5.

  • BS 6004:2012

    Table Number:
    Table 5

    Schedule:
    097/001/152

    Approved Range:
    1.5sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Single-core to Twin-core inclusive. Sheath - Type 6. Insulation - TI1.

  • BS 6004:2012

    Table Number:
    Table 4

    Schedule:
    097/001/153

    Approved Range:
    1sqmm to 1.5sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat twin to flat 3-core inclusive. Class 1 conductor. 4sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat twin to flat 3-core inclusive. Class 2 conductor. Sheath - Type 6. Insulation - TI1. Colour of Sheath: Grey or White.

  • BS 7629-1:2015

    Table Number:
    Table 2

    Schedule:
    097/001/154

    Approved Range:
    1.0sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 2-core to 4-core inclusive. STANDARD 60. Additionally tested to BS 6387 Categories C, W & Z. Sheath - LTS3. Insulation - EI2.

  • BS 7846:2015

    Table Number:
    Table 8

    Schedule:
    097/001/155

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 19-core inclusive. Resistance to fire - Category F2. Sheath - LTS1. Insulation - GP8.

  • BS 7846:2015

    Table Number:
    Tables 4, 5, 6 & 7

    Schedule:
    097/001/156

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Two core to four core inclusive. 1.5sqmm to 70sqmm nominal cross-sectional are of conductors inclusive. Five core. Resistance to fire - Category F2. Sheath - LTS1. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No. 1

    Table Number:
    Table 5,6,7 and 8

    Schedule:
    097/001/157

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. 1.5sqmm to 70 sqmm nominal cross-sectional area of conductors inclusive. Five-core. Sheath - Type 9. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No.1

    Table Number:
    Table 9

    Schedule:
    097/001/158

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 37-core inclusive. Sheath - Type 9. Insulation - GP8.

  • BS 5839-1:2013

    Table Number:
    Standard

    Schedule:
    097/001/159

    Approved Range:
    1sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 2-core to 4-core inclusive. Sheath - LTS3. Insulation - EI2.

  • BS 5467:1997 and A3:2008

    Table Number:
    Tables 6, 8, 10 & 13

    Schedule:
    207/001/005

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. 1.5sqmm to 70sqmm nominal cross-sectional area of conductors inclusive. Five-core. Sheath - Type 9. Insulation - GP8.

  • BS 5467:1997 and A3:2008

    Table Number:
    Table 18

    Schedule:
    207/001/006

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 27-core inclusive. Sheath - Type 9. Insulation - GP8.

Quality (ISO 9001)

  • CS1-174

    Scope:
    The design, manufacture and supply of the following cable types: Power Cables and Cords Armoured and Unarmoured up to 600/1000V. Low Smoke Zero Halogen Cables Armoured and Unarmoured up to 600/1000V. The design and manufacture of: PVC Compounds and LSHF Compounds.

BASEC PCR

  • PCR-174

    Scope:
    The design, manufacture and supply of the following cable types: Power Cables and Cords Armoured and Unarmoured up to 600/1000V. Low Smoke Zero Halogen Cables Armoured and Unarmoured up to 600/1000V. The design and manufacture of: PVC Compounds and LSHF Compounds.