Dubai Cable Company (Private) Limited Visit Website

Licence Number:
083

Origin Mark:
DUCAB A BICC

Dubai Cable Company (Private) Limited
P.O. Box 11529
Dubai
United Arab Emirates

Telephone:
00 971 48082500 (M Pillai Direct tel. 00 971 48082690 & Mobile.00 971 504565479)

Product Schedule

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2

    Table Number:
    Tables 5, 6 and 7

    Schedule:
    083/001/068

    Approved Range:
    1.5sqmm to 50sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. Sheath - LTS1. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No. 1

    Table Number:
    Tables 5, 6 and 7

    Schedule:
    083/001/069

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. Sheath - Type 9. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No. 1

    Table Number:
    Table 4

    Schedule:
    083/001/070

    Approved Range:
    630sqmm to 1000sqmm nominal cross-sectional area of conductors inclusive. Single-core. Sheath - Type 9. Insulation - GP8.

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2

    Table Number:
    Table 9

    Schedule:
    083/001/071

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 37-core inclusive. Sheath - LTS1. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No. 1

    Table Number:
    Table 9

    Schedule:
    083/001/072

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 37-core inclusive. Sheath - Type 9. Insulation - GP8.

  • IEC 60502-2:2014

    Schedule:
    083/001/073

    Approved Range:
    70-300sqmm nominal cross-sectional area of conductors inclusive. 3-core. 70-1000sqmm nominal cross-sectional area of conductors inclusive. Single-core. Bonded extruded conductor screen. XLPE Insulation. Bonded or strippable semi-conducting insulation screen. Copper tape and/or copper wire screened. PVC extruded inner sheath. Galavnised steel round wire armoured (3-core cables). Aluminium round wire armoured (single-core cables). ST2 PVC extruded outer sheath. Voltage ratings 3.6/6(7.2)kV, 6/10(12)kV, 8.7/15(17.5)kV, 12/20(24)kV and 18/30(36)kV. Conforming to IEC 60502-2.

  • BS 6622:2007 Incorporating Corrigenda Nos. 1 and 2

    Schedule:
    083/001/074

    Approved Range:
    70sqmm to 1000sqmm nominal cross-sectional area of conductors inclusive. Single-core. 70sqmm to 300sqmm nominal cross-sectional area of conductors inclusive. 3-core. Stranded circular copper or aluminium conductors (class 2). Extruded semi-conducting conductor screen. XLPE insulation (GP8). Bonded or strippable extruded semi-conducting insulation screen. Copper tape screen. Extruded separation layer (PVC). Galvanised steel wire armour (3-core). Aluminium wire armour (single-core). Extruded PVC oversheath (Type 9).

  • BS 7835:2007 Incorporating Corrigendum No.1

    Schedule:
    083/001/075

    Approved Range:
    70sqmm to 1000sqmm nominal cross-sectional area of conductors inclusive. Single-core. 70sqmm to 300sqmm nominal cross-sectional area of conductors inclusive. 3-core. Stranded circular copper or aluminium conductors (class 2). Extruded semi-conducting conductor screen. XLPE insulation (GP8). Bonded or strippable extruded semi-conducting insulation screen. Copper tape screen. Low smoke zero halogen extruded separation layer (LTS1). Galvanised steel wire armour (3-core). Aluminium wire armour (single-core). Low smoke zero halogen extruded oversheath (LTS1).

  • BS 7846:2009

    Table Number:
    Tables 4, 5, 6 & 7

    Schedule:
    206/001/006

    Approved Range:
    1.5sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Two-core to five-core inclusive. Sheath - LTS1. Insulation - GP8. Resistance to fire - Category F2.

  • BS 5467:1997 and A3:2008

    Table Number:
    Tables 6, 8 and 10

    Schedule:
    206/001/007

    Approved Range:
    1.5sqmm to 25sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. Sheath - Type 9. Insulation - GP8.

  • BS 6724:1997 and A3:2008

    Table Number:
    Tables 6, 8 and 10

    Schedule:
    206/001/008

    Approved Range:
    1.5sqmm to 25sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. Sheath - LTS1. Insulation - GP8.

  • BS 7846:2009

    Table Number:
    Tables 4, 5, & 6

    Schedule:
    206/001/009

    Approved Range:
    4sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. Resistance to fire - Category F120. Sheath - LTS1. Insulation - GP8. This approval is based on the use of 1.25mm armour wire for the following cables: Table 4, two-core, 4, 6 & 10sqmm, Table 5, three-core, 4, 6 & 10sqmm and Table 6, four-core, 4 & 6sqmm.

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    206/001/010

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1, solid conductor. 1.5sqmm to 150sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2, stranded conductor. Insulation - EI5.

  • BS 5467:1997 and A3:2008

    Table Number:
    Tables 6, 8 and 10

    Schedule:
    208/001/003

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. Sheath - Type 9. Insulation - GP8.

  • BS 5467:1997 and A3:2008

    Table Number:
    Tables 6, 8 and 10

    Schedule:
    209/001/003

    Approved Range:
    1.5sqmm to 240sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. Sheath - Type 9. Insulation - GP8 .

Quality (ISO 9001)

  • CS1-144

    Scope:
    The design, manufacture and supply of the following products: Electric Power Cables and Wires Rated up to 132 kV. PVC Compounds

Environmental (ISO 14001)

  • ECS-030

    Scope:
    Management and Control of an Environmental System in respect of the activities at the above site employed in the design, manufacture and supply of: Electric Power Cables and Wires up to 132 kV. PVC Compounds.

Health & Safety (OHSAS 18001)

  • HS-106

    Scope:
    Management and Control of an Occupational Health & Safety System in respect of the activites at the above site employed in the design, manufacture and supply of:: Electric Power Cables and Wires up to 132 kV. PVC Compounds.

BASEC PCR

  • PCR-144

    Scope:
    The design, manufacture and supply of the following cable types: Electric Power Cables and Wires rated up to 132 kV.