Dongguan Keystone Electric Wire & Cable Co Ltd Visit Website

Licence Number:
075

Origin Mark:
<KEYSTONE>

Dongguan Keystone Electric Wire & Cable Co Ltd
Ye Sha Management District
Shatian, Dongguan City
Guangdong 523998
China

Telephone:
00 86 769 8886 7234

Product Schedule

  • BS 6231:2006 Incorporating Corrigendum No.1

    Table Number:
    Table 2

    Schedule:
    075/001/180

    Approved Range:
    0.5sqmm to 240sqmm nominal cross-sectional area of conductors inclusive. Insulation - TI3. Note: The above cables conform to BS 6231 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 7889:1997 Incorporating Amendment Nos. 1, 2 and 3 and Corrigendum No.1

    Table Number:
    Table 4

    Schedule:
    075/001/181

    Approved Range:
    600sqmm to 1200sqmm nominal cross-sectional area of conductors inclusive. Single-core. Sheath - Type 9. Insulation GP8. The core shall be identified by the colours red or black either throughout the insulation or on its external surface. Note: The above cables conform to BS 7889 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 6004:2000 Incorporating Amendment Nos. 1 and 2

    Table Number:
    Table 9

    Schedule:
    075/001/182

    Approved Range:
    1.5sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. With and without circuit protective conductor. Sheath - Type 6. Insulation - TI1. Colour of sheath: White or Grey. Core colour sequence: Single core: red or black, Twin: red and black, or, for 2 x 1sqmm and 2 x 1.5sqmm cables, red and red. Position of circuit protective conductor - Twin: centrally placed between cores in same plane. Note: The above cables conform to BS 6004 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 6004:2000 Incorporating Amendment Nos. 1 and 2

    Table Number:
    Table 8

    Schedule:
    075/001/183

    Approved Range:
    1.0sqmm to 1.5sqmm nominal cross-sectional area of conductors inclusive. Single core. 1.0sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat twin. Sheath - Type 6. Insulation - TI1. Colour of sheath: White or Grey. Core colour sequence - Single core: red or black, Twin: red and black, or, for 2 x 1sqmm and 2 x 1.5sqmm, red and red. Position of circuit protective conductor - Twin: centrally placed between cores in same plane. Note: The above cables conform to BS 6004 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 6500:2000 Incorporating Amendment Nos. 1, 2 and 3 and Corrigendum Nos. 1 and 2

    Table Number:
    Table 27

    Schedule:
    075/001/184

    Approved Range:
    0.75sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Twin-core to 5-core inclusive. Sheath - TM2. Insulation - TI2. Note: The above cables conform to BS 6500 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 6500:2000 Incorporating Amendment Nos. 1, 2 and 3 and Corrigendum Nos. 1 and 2

    Table Number:
    Table 26

    Schedule:
    075/001/185

    Approved Range:
    0.5sqmm to 0.75sqmm nominal cross-sectional area of conductors inclusive. Twin-core to 4-core inclusive. Circular cords only. Sheath - TM2. Insulation - TI2. Note: The above cables conform to BS 6500 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 6004:2000 Incorporating Amendment Nos. 1 and 2

    Table Number:
    Table 4a

    Schedule:
    075/001/186

    Approved Range:
    1.5sqmm to 70sqmm nominal cross-sectional area of conductors inclusive. Single-core. Insulation - TI1. Note: The above cables conform to BS 6004 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 6004:2000 Incorporating Amendment Nos. 1 and 2

    Table Number:
    Table 5

    Schedule:
    075/001/187

    Approved Range:
    0.5sqmm to 1sqmm nominal cross-sectional area of conductors inclusive. Single-core. Insulation - TI1. Note: The above cables conform to BS 6004 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 7919:2001 Incorporating Amendment Nos. 1, 2 and 3

    Table Number:
    Table 40

    Schedule:
    075/001/188

    Approved Range:
    4sqmm nominal cross-sectional area of conductors inclusive. Twin-core to 5-core inclusive. Sheath - TM2. Insulation - TI2. Note: The above cables conform to BS 7919 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 7889:1997 Incorporating Amendment Nos. 1, 2 and 3 and Corrigendum No.1

    Table Number:
    Table 4

    Schedule:
    075/001/189

    Approved Range:
    600sqmm to 1200sqmm nominal cross-sectional area of conductors inclusive. Single-core. 960sqmm nominal cross-sectional area of conductor which shall comprise of four sector shaped sections laid up together. Sheath - Type 9. Insulation - GP8. Note: The above cables conform to BS 7889 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 6004:2000 Incorporating Amendment Nos. 1 and 2

    Table Number:
    Table 9

    Schedule:
    075/001/190

    Approved Range:
    1.5sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. With and without circuit protective conductor. Sheath - Type 6. Insulation - TI1. Colour of sheath: White or Grey. Note: The above cables conform to BS 6004 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 6004:2000 Incorporating Amendment Nos. 1 and 2

    Table Number:
    Table 8

    Schedule:
    075/001/191

    Approved Range:
    1.0sqmm to 1.5sqmm nominal cross-sectional area of conductors inclusive. Single core. 1.0sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat twin. Sheath - Type 6. Insulation - TI1. Colour of sheath: White or Grey. Note: The above cables conform to BS 6004 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 7889:1997 Incorporating Amendment Nos. 1, 2 and 3 and Corrigendum No.1

    Table Number:
    Table 4

    Schedule:
    075/001/192

    Approved Range:
    600sqmm to 1200sqmm nominal cross-sectional area of conductors inclusive. Single-core. 960sqmm nominal cross-sectional area of conductor which shall comprise of four 'solid' sector shaped sections laid up together. Sheath - Type 9. Insulation - GP8. Note: The above cables conform to BS 7889 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • IEC 60502-1 Edition 2.1:2009

    Schedule:
    075/001/193

    Approved Range:
    6sqmm to 1000sqmm nominal cross-sectional area of conductors inclusive. Single core. Sheath - ST8. Insulation - XLPE. Note: The above cables conform to IEC 60502-1 and, by reference, conform to the appropriate requirements of: IEC 60228, IEC 60332-3-24 Cat C, IEC 60332-1-2, IEC 61034-2, IEC 60684-2 and IEC 60754 specifications

  • IEC 60227-3:1993 Incorporating Amendment No.1 1997

    Table Number:
    Table 9

    Schedule:
    075/001/194

    Approved Range:
    0.5sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Single-core. Insulation - PVC/E. Note: The above cables conform to IEC 60227-3 and, by reference, conform to the appropriate requirements of IEC 60228.

  • BS 6004:2000 Incorporating Amendment Nos. 1 and 2

    Table Number:
    Table 7

    Schedule:
    075/001/195

    Approved Range:
    1.0sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Single core to Flat twin inclusive. 35sqmm nominal cross-sectional area of conductor inclusive. Single-core. Sheath - Type 6. Insulation - TI1. Colour of sheath, single-core: White, grey, black, red, blue or brown. Colour of sheath, flat-twin: White or grey. Core colour sequence - Single-core: red or black, Twin: red and black, or, for 2 x 1sqmm and 2 x 1.5sqmm cables, red and red. Note: The above cables conform to BS 6004 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 6004:2000 Incorporating Amendment Nos. 1 and 2

    Table Number:
    Table 7

    Schedule:
    075/001/196

    Approved Range:
    1.0sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Single core to Flat twin inclusive. 35sqmm nominal cross-sectional area of conductor inclusive. Single-core. Sheath - Type 6. Insulation - TI1. Colour of sheath, single-core: White, grey, black, red, blue or brown. Colour of sheath, flat-twin: White or grey. Note: The above cables conform to BS 6004 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 6622:2007 Incorporating Corrigenda Nos. 1 and 2

    Schedule:
    075/001/198

    Approved Range:
    70sqmm to 800sqmm nominal cross-sectional area of conductors inclusive. Single-core. 70sqmm to 300sqmm nominal cross-sectional area of conductors inclusive. 3-core. Stranded circular copper or alluminium conductors (class 2). Extruded semi-conducting conductor screen. XLPE insulation. Bonded or strippable extruded semi-conducting insulation screen. Copper tape and/or copper wire screened. PVC or PE bedding extruded inner sheath. Galvanised steel wire armour (3-core). Aluminium wire armour (single core). PVC Type 9 or MDPE (TS2) extruded oversheath. Note: The above cables conform to BS 6622 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 6004:2012

    Table Number:
    Table 3

    Schedule:
    075/001/200

    Approved Range:
    1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Single-core to flat twin inclusive. Class 1 conductor. 4sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. 4sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat twin. Sheath - Type 6. Insulation - TI1. Note: The above cables conform to BS 6004 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 6004:2012

    Table Number:
    Table 4

    Schedule:
    075/001/201

    Approved Range:
    1sqmm to 1.5sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat twin. Class 1 conductor. 4sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat twin. Class 2 conductor. Sheath - Type 6. Insulation - TI1. Note: The above cables conform to BS 6004 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 6004:2012

    Table Number:
    Table 5

    Schedule:
    075/001/202

    Approved Range:
    1.5sqmm nominal cross-sectional area of conductor. Single-core. Class 2 conductor, with CPC. 1.5sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat twin. Class 2 conductor, with and without CPC. Sheath - Type 6. Insulation - TI1. Note: The above cables conform to BS 6004 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS EN 50525-2-11:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    075/001/203

    Approved Range:
    0.5sqmm to 0.75sqmm nominal cross-sectional area of conductors inclusive. 2-core to 4-core inclusive. Class 5 conductor. Circular cables. Sheath - TM2. Insulation - TI2. Note: The above cables conform to BS EN 50525-2-11 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS EN 50525-2-11:2011

    Table Number:
    Clause 4.2 Table B.2

    Schedule:
    075/001/204

    Approved Range:
    0.75sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 2-core to 5-core inclusive. Class 5 conductor. Circular cables. Sheath - TM2. Insulation - TI2. Note: The above cables conform to BS EN 50525-2-11 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    075/001/205

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.5sqmm to 70sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - TI1. Note: The above cables conform to BS EN 50525-2-31 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.3 Table B.3

    Schedule:
    075/001/206

    Approved Range:
    0.5sqmm to 1sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 & 2 conductor. Insulation - TI1. Note: The above cables conform to BS EN 50525-2-31 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.4 Table B.4

    Schedule:
    075/001/207

    Approved Range:
    0.5sqmm to 1sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - TI1. Note: The above cables conform to BS EN 50525-2-31 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 7889:2012

    Table Number:
    Tables 3, 4 & 5

    Schedule:
    075/001/208

    Approved Range:
    1.5sqmm to 120sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. Class 2 circular conductor. 25sqmm to 120sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. Class 2 shaped conductor. Sheath - Type 9. Insulation - GP8. Any core colour sequence meeting regulatory requirements. Note: The above cables conform to BS 7889 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 7889:2012

    Table Number:
    Table 2

    Schedule:
    075/001/209

    Approved Range:
    1.5sqmm to 1000sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Sheath - Type 9. Insulation - GP8. Any core colour sequence meeting regulatory requirements. Note: The above cables conform to BS 7889 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 7211:1998 Incorporating Amendments Nos. 1 and 2

    Table Number:
    Table 3a

    Schedule:
    075/001/210

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Single-core. Insulation - EI5. Note: The above cables conform to BS 7211 and, by reference, conform to the appropriate requirements of: BS EN 60228, BS EN 60332-1-2, BS EN 61034-2 and BS EN 60754-2 specifications

  • BS 7211:1998 Incorporating Amendments Nos. 1 and 2

    Table Number:
    Table 3b

    Schedule:
    075/001/211

    Approved Range:
    1.5sqmm to 240sqmm nominal cross-sectional area of conductors inclusive. Single-core. Insulation - EI5. Note: The above cables conform to BS 7211 and, by reference, conform to the appropriate requirements of: BS EN 60228, BS EN 60332-1-2, BS EN 61034-2 and BS EN 60754-2 specifications

  • BS 7211:1998 Incorporating Amendments Nos. 1 and 2

    Table Number:
    Table 4b

    Schedule:
    075/001/212

    Approved Range:
    0.5sqmm to 1.0sqmm nominal cross-sectional area of conductors inclusive. Single-core. Insulation - EI5. Note: The above cables conform to BS 7211 and, by reference, conform to the appropriate requirements of: BS EN 60228, BS EN 60332-1-2, BS EN 61034-2 and BS EN 60754-2 specifications

  • BS 7211:1998 Incorporating Amendments Nos. 1 and 2

    Table Number:
    Table 4a

    Schedule:
    075/001/213

    Approved Range:
    0.5sqmm to 1.0sqmm nominal cross-sectional area of conductors inclusive. Single-core. Insulation - EI5. Note: The above cables conform to BS 7211 and, by reference, conform to the appropriate requirements to: BS EN 60228, BS EN 60332-1-2, BS EN 61034-2 and BS EN 60754-2 specifications

  • BS 7835:2007 Incorporating Corrigendum No.1

    Schedule:
    075/001/214

    Approved Range:
    70sqmm to 800sqmm nominal cross-sectional area of conductors inclusive. Single-core. 70sqmm to 300sqmm nominal cross-sectional area of conductors inclusive. 3-core. Stranded circular copper or alluminium conductors (class 2). Extruded semi-conducting conductor screen. XLPE insulation. Bonded or strippable extruded semi-conducting insulation screen. Copper tape and/or copper wire screened. Low smoke, non-halogen extruded inner sheath. Galvanised steel wire armour (3-core). Aluminium wire armour (single core). Low smoke, non-halogen extruded oversheath. Note: The above cables conform to BS 7835 and, by reference, conform to the appropriate requirements of BS EN 60228, BS EN 60332-3-24, BS EN 60332-1-2, BS EN 61034-2 and BS EN 60754-1 specifications.

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    075/001/215

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - EI5. Note: The above cables conform to BS EN 50525-3-41 and, by reference, conform to the appropriate requirements of: BS EN 60228, BS EN 60332-1-2, BS EN 61034-2, BS EN 60754-1, BS EN 60754-2 and BS EN 60684-2 specifications.

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.2 Table B.2

    Schedule:
    075/001/216

    Approved Range:
    1.5sqmm to 240sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - EI5. Note: The above cables conform to BS EN 50525-3-41 and, by reference, conform to the appropriate requirements of: BS EN 60028, BS EN 60332-1-2, BS EN 61034-2, BS EN 60754-1, BS EN 60754-2 and BS EN 60684-2 specifications.

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.3 Table B.3

    Schedule:
    075/001/217

    Approved Range:
    0.5sqmm to 1sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. Insulation - EI5. Note: The above cables conform to BS EN 50525-3-41 and, by reference, conform to the appropriate requirements of: BS EN 60228, BS EN 60332-1-2, BS EN 61034-2, BS EN 60754-1, BS EN 60754-2 and BS EN 60684-2 specifications.

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.4 Table B.4

    Schedule:
    075/001/218

    Approved Range:
    0.5sqmm to 1sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - EI5. Note: The above cables conform to BS EN 50525-3-41 and, by reference, conform to the appropriate requirements of: BS EN 60228, BS EN 60332-1-2, BS EN 61034-2, BS EN 60754-1, BS EN 60754-2 and BS EN 60684-2 specifications.

  • BS 7211:2012

    Table Number:
    Table 4

    Schedule:
    075/001/219

    Approved Range:
    1.0sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Twin-core to 4-core inclusive. Class 1 conductor. 1.0sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Twin-core to 4-core inclusive. Class 2 conductor. Sheath - LTS4. Insulation - EI5. Note: The above cables conform to BS 7211 and, by reference, conform to the appropriate requirements of BS EN 60288, BS EN 60332-1-2, BS EN 60332-3-24, BS EN 61034-2 and BS EN 60754-1 specifications.

  • BS 7211:2012

    Table Number:
    Table 5

    Schedule:
    075/001/220

    Approved Range:
    1.0sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat twin. Class 1 conductor. 1.0sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat twin. Class 2 conductor. Sheath - LTS2. Insulation - GP8. Note: The above cables conform to BS 7211 and, by reference, conform to the appropriate requirements of BS EN 60228, BS EN 60332-1-2, BS EN 61034-2 and BS EN 60754-1 specifications.

  • BS 7846:2015

    Table Number:
    Tables 4, 5 & 6

    Schedule:
    075/001/221

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. Resistance to Fire - Category F2. Sheath - LTS1. Insulation - GP8. Note: The above cables conform to BS 7846 and, by reference, conform to the appropriate requirements of: BS EN 60228, BS EN 60332-1-2, BS EN 60332-3-24, BS EN 61034-2, BS EN 60754-1 and BS 6387 C,W & Z specifications. The above cables have been additional tested to: BS EN 60754-2 and BS EN 60684-2.

  • BS 7846:2015

    Table Number:
    Table 8

    Schedule:
    075/001/222

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 37-core inclusive. Resistance to Fire - Category F2. Sheath - LTS1. Insulation - GP8. Note: The above cables conform to BS 7846 and, by reference, conform to the appropriate requirements of: BS EN 60228, BS EN 60332-1-2, BS EN 60332-3-24, BS EN 61034-2, BS EN 60754-1 and BS 6387 C,W & Z specifications. The above cables have been additional tested to: BS EN 60754-2 and BS EN 60684-2.

  • BS 7889:1997 Incorporating Amendment Nos. 1, 2 and 3 and Corrigendum No.1

    Table Number:
    Table 4

    Schedule:
    075/001/223

    Approved Range:
    600sqmm to 1200sqmm nominal cross-sectional area of conductors inclusive. Single-core. 960sqmm nominal cross-sectional area of conductor which shall comprise of four 'solid' sector shaped sections laid up together. Sheath - Type 9. Insulation - GP8. The core shall be identified by the colours red or black either throughout the insulation or on its external surface. Note: The above cables conform to BS 7889 and, by reference, conform to the appropriate requirements of BS EN 60228.

  • BS 7846:2015

    Table Number:
    Tables 4, 5 & 6

    Schedule:
    075/001/224

    Approved Range:
    10sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Two-core. Class 2 conductor. 4sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Three-core to four-core inclusive. Class 2 conductor. Resistance to Fire - Category F120. Sheath - LTS1. Insulation - GP8. Note: The above cables conform to BS 7846 and, by reference, conform to the appropriate requirements of: BS EN 60228, BS EN 60332-1-2, BS EN 60332-3-24, BS EN 61034-2, BS EN 60754-1, BS 8491 and BS 6387 C,W & Z specifications.

  • IEC 60502-2:2014

    Schedule:
    075/001/225

    Approved Range:
    Up to 300sqmm nominal cross-sectional area of conductors inclusive. 3-core. Up to 800sqmm nominal cross-sectional area of conductors inclusive. Single-core. XLPE Insulation. Bonded or strippable semi-conducting insulation screen. Copper tape and/or copper wire screened. Low smoke, zero halogen, extruded inner sheath. Galvanised steel round wire armoured (3-core cables). Aluminium round wire armoured (single-core cables). ST8 low smoke, zero halogen, extruded outer sheath. Voltage ratings: 3,6/6(7,2)kV, 6/10(12)kV, 8.7/15(17.5)kV, 12/20(22)kV and 18/30(36)kV. Generally to IEC 60502-2 and including IEC 60228, IEC 60332-3.24, IEC 61034, IEC 60684-2 and IEC 60754 specifications.

  • IEC 60502-2:2014

    Schedule:
    075/001/226

    Approved Range:
    Up to 300sqmm nominal cross-sectional area of conductors inclusive. 3-core. Up to 800sqmm nominal cross-sectional area of conductors inclusive. Single-core. Conductor to IEC 60228. XLPE Insulation. Bonded or strippable semi-conducting insulation screen. Copper tape and/or copper wire screened. PVC or PE extruded inner sheath. Galvanised steel round wire armoured (3-core cables). Aluminium round wire armoured (single-core cables). PVC (ST2) or MDPE (ST7) extruded outer sheath. Voltage ratings: 3,6/6(7,2)kV, 6/10(12)kV, 8.7/15(17.5)kV, 12/20(22)kV and 18/30(36)kV. Note: The above cables conform to IEC 60502-2 and, by reference, conform to the appropriate requirements of IEC 60228.

Quality (ISO 9001)

  • CS1-129

    Scope:
    The design, manufacture and supply of the following cable types and products: Energy Cables rated up to 36kV, Rubber Cables up to 36kV, Branch Cables up to 1k. Control Cables. Telecommunications Cables up to 100 pairs and frequency to 150MHz. Category 5 Cables to 5E. PVC Compounds. Materials used: Copper, Aluminium, GSW, PE, PVC, XLPE. Low Smoke Halogen Free and Elastomeric Compounds.

BASEC PCR

  • PCR-129

    Scope:
    The design, manufacture and supply of the following cable types and products: Energy Cables rated up to 1kV. Rubber Cables up to 36 kV, Branch Cables up to 1kV. Control Cables, Telecommunicaton cables up to 100 pairs and frequency to 150MHz. Category 5 Cables to 5E. PVC Compounds. Materials used: Copper, Aluminium, GSW, PE, PVC, XLPE. Low Smoke Halogen Free and Elastomeric Compounds.