Prysmian Cables & Systems Ltd Visit Website

Licence Number:
017

Origin Mark:
PRYSMIAN (B) or (B) PRYSMIAN or BRITCABLE (B) or (B) BRITCABLE or PRYSMIAN (B) FP400 or (B) PRYSMIAN FP400 or PRYSMIAN (B) FP600S or (B) PRYSMIAN FP600S or BRITCABLE (B) FP400 or (B) BRITCABLE FP400 or BRITCABLE (B) FP600S or (B) BRITCABLE FP600S or DRAKA UK (B) or DRAKA UK (B) FIRETUF POWER PLUS or DRAKA UK (B) FTP120 or DRAKA UK (B) FIRETUF POWER or DRAKA UK (B) FTP

Prysmian Cables & Systems Ltd
Chickenhall Lane
Eastleigh, Hampshire
United Kingdom

Telephone:
08705 133143

Products (Filtered of )

Filters (1) Edit filter

  • BS EN 50525-3-41:2011
    View Certificate PDF 435KB

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    017/004/316

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Single-core. Non HAR colours; yellow, green and combinations of other colours. Class 2 conductor. Insulation - EI5.

  • BS EN 50525-3-41:2011
    View Certificate PDF 509KB

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    017/004/317

    Approved Range:
    1.5sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - EI5.

  • BS EN 50525-2-31:2011
    View Certificate PDF 511KB

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    017/004/318

    Approved Range:
    1.5sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - TI1.

  • BS EN 50525-2-31:2011
    View Certificate PDF 426KB

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    017/004/319

    Approved Range:
    1.5sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Non HAR colours; yellow, green and combinations of other colours. Insulation - TI1.

  • BS 7889:2012
    View Certificate PDF 401KB

    Table Number:
    Table 2

    Schedule:
    017/004/320

    Approved Range:
    1.5sqmm to 95sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Sheath - Type 9. Insulation - GP8.

  • BS 7629-1:1997 Incorporating Amendment Nos. 1 and 2
    View Certificate PDF 404KB

    Table Number:
    Table 2

    Schedule:
    017/004/321

    Approved Range:
    1.5sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. Class 1 and Class 2 conductors. Sheath - LTS3. Insulation - EI5.

  • BS 7629-1:1997 Incorporating Amendment Nos. 1 and 2
    View Certificate PDF 407KB

    Table Number:
    Table 2

    Schedule:
    017/004/322

    Approved Range:
    2.5sqmm nominal cross-sectional area of conductor. 19-core. Sheath - LTS3. Insulation - EI5.

  • BS 7629-1:1997 Incorporating Amendment Nos. 1 and 2
    View Certificate PDF 456KB

    Table Number:
    Table 2

    Schedule:
    017/004/323

    Approved Range:
    1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. 2-core to 4-core inclusive. Class 1 and Class 2 conductors. Sheath - LTS3. Insulation - EI5. Core colour sequence - Two-core plus uninsulated CPC: red, black, Three-core plus uninsulated CPC: red, yellow, blue, Four-core plus uninsulated CPC: red, yellow, blue, black.

  • BS 7629-1:2015
    View Certificate PDF 416KB

    Table Number:
    Table 2

    Schedule:
    017/004/324

    Approved Range:
    1.5 to 4.0sqmm nominal cross-sectional area of conductors inclusive. 2-core to 4-core inclusive. STANDARD 60. Additionally tested to BS 6387:2013 Categories C, W & Z. Sheath - LTS3. EI5 Insulation.

  • BS 7629-1:2015
    View Certificate PDF 415KB

    Table Number:
    Table 2

    Schedule:
    017/004/325

    Approved Range:
    1.5sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. 2-core to 4-core inclusive. ENHANCED 120. Additionally tested to BS 6387:2013 Categories C, W & Z. Sheath - LTS3. Insulation - EI5.

  • BS 7629-1:2015
    View Certificate PDF 421KB

    Table Number:
    Table 2

    Schedule:
    017/004/326

    Approved Range:
    1.0sqmm to 4.0sqmm nominal cross-sectional area of conductors inclusive. 2-core to 4-core inclusive. ENHANCED 120. Additionally tested to BS 6387:2013 Categories C, W & Z. Sheath LTS3. Insulation - EI5.

  • BS 7629-1:2015
    View Certificate PDF 441KB

    Table Number:
    Table 2 & Table 3

    Schedule:
    017/004/327

    Approved Range:
    1.0sqmm nominal cross-sectional area of conductors. 2-core. 1.5sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. 7-core to 12-core inclusive. 1.5sqmm nominal cross-sectional area of conductors. 19-core. STANDARD 30. Additionally tested to BS 6387:2013 Categories C, W & Z. Sheath - LTS3. Insualtion - EI5.

  • BS 7846:2015
    View Certificate PDF 416KB

    Table Number:
    Table 8

    Schedule:
    017/004/328

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 37-core inclusive. Resistance to fire - Category F2. Sheath - LTS1. Insulation - GP8.

  • BS 7846:2015
    View Certificate PDF 469KB

    Table Number:
    Tables 4, 5, 6 & 7

    Schedule:
    017/004/330

    Approved Range:
    4sqmm to 70sqmm nominal cross-sectional area of conductors inclusive. Two-core and three-core inclusive. 4sqmm to 50sqmm nominal cross-sectional area of conductors inclusive. Four-core. 4sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Five-core. Resistance to fire - Category F120. Sheath - LTS1. Insulation - GP8. This approval is based on the use of 1.25mm armour wire for the following cables: Table 4, two-core, 4, 6 & 10sqmm, Table 5, three-core, 4 & 6 sqmm and Table 6, four-core, 4sqm, Table 7, five-core, 4sqmm.

  • BS 8436:2011
    View Certificate PDF 409KB

    Table Number:
    Table 1

    Schedule:
    017/004/331

    Approved Range:
    1.0sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 2-core to 4-core inclusive with uninsulated circuit protective conductor. Sheath - LTS3. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No. 1
    View Certificate PDF 413KB

    Table Number:
    Table 9

    Schedule:
    017/004/332

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 37-core inclusive. Sheath - Type 9. Insulation - GP8.

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2
    View Certificate PDF 424KB

    Table Number:
    Table 9

    Schedule:
    017/004/333

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 37-core inclusive. Sheath - LTS1. Insulation - GP8.

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2
    View Certificate PDF 441KB

    Table Number:
    Tables 5, 6, 7 & 8

    Schedule:
    017/004/334

    Approved Range:
    1.5sqmm to 70sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. 1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Five-core. Sheath - LTS1. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No. 1
    View Certificate PDF 449KB

    Table Number:
    Tables 5, 6, 7 & 8

    Schedule:
    017/004/335

    Approved Range:
    1.5sqmm to 70sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. 1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Five-core. Sheath - Type 9. Insulation - GP8.

  • BS 7846:2015
    View Certificate PDF 439KB

    Table Number:
    Tables 4, 5, 6 & 7

    Schedule:
    017/004/336

    Approved Range:
    1.5sqmm to 70sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. 1.5sqmm to 10sqmm nominal cross sectional area of conductors inclusive. Five-core. Resistance to fire - Category F2. Sheath - LTS1. Insulation - GP8.

BASEC CPR

  • CPR-005

    Scope:
    Power Cables

Quality (ISO 9001)

  • CS1-084
    View Certificate PDF 1.4MB

    Scope:
    Corporate Management and Administrative functions for the UK Business and Factories. The design, development, manufacture and supply of: Energy cables for Special, Industrial, Fire Performance Applications up to 1.0 kV using PVC, Polymeric & Elastomeric Compounds. The design, development and manufacture of: Low Smoke and Special Cable Compounds

BASEC PCR

  • PCR-084
    View Certificate PDF 1.5MB

    Scope:
    The design, development, manufacture and supply of: Energy cables for Special, Industrial and Fire Performance Applications up to 1.kV using PVC, Polymeric & Elastomeric Compounds. The design, development and manufacture of: Low smoke and Special Cable Compounds.

CPR Classification Reports

  • BS 5467 1kV Single Core Conductor

    Report No. KCPRT0938-7

    Issue Date: 17th October 2017

  • I.S. 201-4: 2013

    Report No. LCPR1326

    Issue Date: 3rd August 2017

  • Family 14 - BS EN 50525-3-41 H07Z-R Single Core

    Report No. L3CPRT130

    Issue Date: 30th June 2017

  • Family 22 - BS 7835 11kV Single Core Conductor

    Report No. L1CPRT130-1

    Issue Date: 22nd May 2017

  • Family 23 - BS 7835 11kV 3 Core Conductor

    Report No. L1CPRT130-2

    Issue Date: 22nd May 2017

  • BS EN 50525-3-41 (H07Z-U/R)

    Report No. KCPR0952-1

    Issue Date: 17th May 2017

  • Family 17 - BS 6724 Small Circular Conductor

    Report No. KCPR0972

    Issue Date: 26th April 2017

  • Family 14 - BS EN 50525-3-41 H07Z-R Single Core

    Report No. K1CPRT063-1

    Issue Date: 25th April 2017

  • Family 18 - BS 6724 Large Circular Conductor

    Report No. K1CPRT063-2

    Issue Date: 25th April 2017

  • Family 19 - BS 6724 Multicore Shaped Conductor

    Report No. K1CPRT063-3

    Issue Date: 25th April 2017

  • Family 20 - BS 6724 Single Core

    Report No. K1CPRT063-4

    Issue Date: 25th April 2017

  • BS 7211 (624-B)

    Report No. KCPR0970

    Issue Date: 22nd March 2017

  • Family 16 - BS 8436

    Report No. KCPR0971

    Issue Date: 22nd March 2017

  • BS EN 50525-2-31 (6491X)

    Report No. KCPRT0938-1

    Issue Date: 22nd March 2017

  • BS 7889

    Report No. KCPRT0938-4

    Issue Date: 22nd March 2017

  • BS EN 50525-3-41 (H07Z-U/R)

    Report No. KCPR0952-2

    Issue Date: 6th February 2017

  • BS 6622 11kV 3-Core

    Report No. KCPRT0938-12

    Issue Date: 7th November 2016

  • BS 6004 (6181Y)

    Report No. KCPRT0938-2

    Issue Date: 7th November 2016

  • BS 6004

    Report No. KCPRT0938-3

    Issue Date: 7th November 2016

  • BS 5467 1kV Circular Conductor

    Report No. KCPRT0938-5

    Issue Date: 7th November 2016

  • BS 5467 1kV Shaped Conductor

    Report No. KCPRT0938-6

    Issue Date: 7th November 2016

  • IEC 60502-1 1kV SCA AWA

    Report No. KCPRT0938-8

    Issue Date: 7th November 2016

  • IEC 60502-1 1kV SCA

    Report No. KCPRT0938-9

    Issue Date: 7th November 2016

Certificates of Constancy of Performance

  • BS EN 50525-3-41 H07Z-R Single Core

    Certificate No. 2661-CPR-0006

    Issue Date: 29th June 2017

  • BS 6724 Large Circular Conductor

    Certificate No. 2661-CPR-0007

    Issue Date: 24th April 2017

  • BS 6724 Multicore Shaped Conductor

    Certificate No. 2661-CPR-0009

    Issue Date: 24th April 2017