Prysmian Cables & Systems Ltd Visit Website

Licence Number:
017

Origin Mark:
PRYSMIAN (B) or (B) PRYSMIAN or BRITCABLE (B) or (B) BRITCABLE or PRYSMIAN (B) FP400 or (B) PRYSMIAN FP400 or PRYSMIAN (B) FP600S or (B) PRYSMIAN FP600S or BRITCABLE (B) FP400 or (B) BRITCABLE FP400 or BRITCABLE (B) FP600S or (B) BRITCABLE FP600S or DRAKA UK (B) or DRAKA UK (B) FIRETUF POWER PLUS or DRAKA UK (B) FTP120 or DRAKA UK (B) FIRETUF POWER or DRAKA UK (B) FTP

Prysmian Cables & Systems Ltd
Chickenhall Lane
Eastleigh, Hampshire
United Kingdom

Telephone:
08705 133143

Product Schedule

  • BS 6004:2000 Incorporating Amendment Nos. 1 and 2

    Table Number:
    Table 7

    Schedule:
    017/004/315

    Approved Range:
    1sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Single core. Sheath - Type 6. Insulation - TI1.

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    017/004/316

    Approved Range:
    1.5sqmm to 400sqmm nominal cross-sectional area of conductors inclusive. Single-core. Non HAR colours; yellow, green and combinations of other colours. Class 2 conductor. Insulation - EI5.

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    017/004/317

    Approved Range:
    1.5sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - EI5.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    017/004/318

    Approved Range:
    1.5sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - TI1.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    017/004/319

    Approved Range:
    1.5sqmm to 630sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Non HAR colours; yellow, green and combinations of other colours. Insulation - TI1.

  • BS 7889:2012

    Table Number:
    Table 2

    Schedule:
    017/004/320

    Approved Range:
    1.5sqmm to 95sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Sheath - Type 9. Insulation - GP8.

  • BS 7629-1:1997 Incorporating Amendment Nos. 1 and 2

    Table Number:
    Table 2

    Schedule:
    017/004/321

    Approved Range:
    1.5sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. Class 1 and Class 2 conductors. Sheath - LTS3. Insulation - EI5.

  • BS 7629-1:1997 Incorporating Amendment Nos. 1 and 2

    Table Number:
    Table 2

    Schedule:
    017/004/322

    Approved Range:
    2.5sqmm nominal cross-sectional area of conductor. 19-core. Sheath - LTS3. Insulation - EI5.

  • BS 7629-1:1997 Incorporating Amendment Nos. 1 and 2

    Table Number:
    Table 2

    Schedule:
    017/004/323

    Approved Range:
    1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. 2-core to 4-core inclusive. Class 1 and Class 2 conductors. Sheath - LTS3. Insulation - EI5. Core colour sequence - Two-core plus uninsulated CPC: red, black, Three-core plus uninsulated CPC: red, yellow, blue, Four-core plus uninsulated CPC: red, yellow, blue, black.

  • BS 7629-1:2015

    Table Number:
    Table 2

    Schedule:
    017/004/324

    Approved Range:
    1.5 to 4.0sqmm nominal cross-sectional area of conductors inclusive. 2-core to 4-core inclusive. STANDARD 60. Additionally tested to BS 6387:2013 Categories C, W & Z. Sheath - LTS3. EI5 Insulation.

  • BS 7629-1:2015

    Table Number:
    Table 2

    Schedule:
    017/004/325

    Approved Range:
    1.5sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. 2-core to 4-core inclusive. ENHANCED 120. Additionally tested to BS 6387:2013 Categories C, W & Z. Sheath - LTS3. Insulation - EI5.

  • BS 7629-1:2015

    Table Number:
    Table 2

    Schedule:
    017/004/326

    Approved Range:
    1.0sqmm to 4.0sqmm nominal cross-sectional area of conductors inclusive. 2-core to 4-core inclusive. ENHANCED 120. Additionally tested to BS 6387:2013 Categories C, W & Z. Sheath LTS3. Insulation - EI5.

  • BS 7629-1:2015

    Table Number:
    Table 2 & Table 3

    Schedule:
    017/004/327

    Approved Range:
    1.0sqmm nominal cross-sectional area of conductors. 2-core. 1.5sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. 7-core to 12-core inclusive. 1.5sqmm nominal cross-sectional area of conductors. 19-core. STANDARD 30. Additionally tested to BS 6387:2013 Categories C, W & Z. Sheath - LTS3. Insualtion - EI5.

  • BS 7846:2015

    Table Number:
    Table 8

    Schedule:
    017/004/328

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 37-core inclusive. Resistance to fire - Category F2. Sheath - LTS1. Insulation - GP8.

  • BS 7846:2015

    Table Number:
    Tables 4, 5, 6 & 7

    Schedule:
    017/004/330

    Approved Range:
    4sqmm to 70sqmm nominal cross-sectional area of conductors inclusive. Two-core and three-core inclusive. 4sqmm to 50sqmm nominal cross-sectional area of conductors inclusive. Four-core. 4sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Five-core. Resistance to fire - Category F120. Sheath - LTS1. Insulation - GP8. This approval is based on the use of 1.25mm armour wire for the following cables: Table 4, two-core, 4, 6 & 10sqmm, Table 5, three-core, 4 & 6 sqmm and Table 6, four-core, 4sqm, Table 7, five-core, 4sqmm.

  • BS 8436:2011

    Table Number:
    Table 1

    Schedule:
    017/004/331

    Approved Range:
    1.0sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 2-core to 4-core inclusive with uninsulated circuit protective conductor. Sheath - LTS3. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No. 1

    Table Number:
    Table 9

    Schedule:
    017/004/332

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 37-core inclusive. Sheath - Type 9. Insulation - GP8.

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2

    Table Number:
    Table 9

    Schedule:
    017/004/333

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 37-core inclusive. Sheath - LTS1. Insulation - GP8.

  • BS 6724:2016 Incorporating Corrigenda Nos. 1 and 2

    Table Number:
    Tables 5, 6, 7 & 8

    Schedule:
    017/004/334

    Approved Range:
    1.5sqmm to 70sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. 1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Five-core. Sheath - LTS1. Insulation - GP8.

  • BS 5467:2016 Incorporating Corrigendum No. 1

    Table Number:
    Tables 5, 6, 7 & 8

    Schedule:
    017/004/335

    Approved Range:
    1.5sqmm to 70sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. 1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Five-core. Sheath - Type 9. Insulation - GP8.

  • BS 7846:2015

    Table Number:
    Tables 4, 5, 6 & 7

    Schedule:
    017/004/336

    Approved Range:
    1.5sqmm to 70sqmm nominal cross-sectional area of conductors inclusive. Two-core to four-core inclusive. 1.5sqmm to 10sqmm nominal cross sectional area of conductors inclusive. Five-core. Resistance to fire - Category F2. Sheath - LTS1. Insulation - GP8.

Quality (ISO 9001)

  • CS1-084

    Scope:
    Corporate Management and Administrative functions for the UK Business and Factories. The design, development, manufacture and supply of: Energy cables for Special, Industrial, Fire Performance Applications up to 1.0 kV using PVC, Polymeric & Elastomeric Compounds. The design, development and manufacture of: Low Smoke and Special Cable Compounds

BASEC PCR

  • PCR-084

    Scope:
    The design, development, manufacture and supply of: Energy cables for Special, Industrial and Fire Performance Applications up to 1.kV using PVC, Polymeric & Elastomeric Compounds. The design, development and manufacture of: Low smoke and Special Cable Compounds.

CPR