Doncaster Cables Visit Website

Licence Number:
040

Origin Mark:
DONCASTER CABLES or CLIPSAL or GB CABLES or LYON CABLES

Doncaster Cables
Millfields Industrial Estate
Arksey Lane, Bentley
Doncaster, South Yorkshire
United Kingdom

Telephone:
01302 821720

Product Schedule

  • BS 4553-1:1998 Incorporating Amendment Nos. 1 and 2

    Table Number:
    Table 3

    Schedule:
    040/001/328

    Approved Range:
    4sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Sheath - TM1 and Insulation - TI1.

  • BS 6231:2006 Incorporating Corrigendum No.1

    Table Number:
    Table 2

    Schedule:
    040/001/329

    Approved Range:
    0.5sqmm to 95sqmm nominal cross-sectional area of conductors inclusive. Insulation - TI3

  • BS 5467:1997 and A3:2008

    Table Number:
    Tables 6, 8, 10 and 13

    Schedule:
    040/001/330

    Approved Range:
    1.5sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Two-core to five-core inclusive. Sheath - Type 9. Insulation - GP8.

  • BS 5467:1997 and A3:2008

    Table Number:
    Table 18

    Schedule:
    040/001/331

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 19-core inclusive. Sheath - Type 9. Insulation - GP8.

  • BS 6724:1997 and A3:2008

    Table Number:
    Tables 6, 8, 10 and 13

    Schedule:
    040/001/332

    Approved Range:
    1.5sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Two-core to five-core inclusive. Sheath - LTS1. Insulation - GP8.

  • BS 6724:1997 and A3:2008

    Table Number:
    Table 18

    Schedule:
    040/001/333

    Approved Range:
    1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 7-core to 19-core inclusive. Sheath - LTS1. Insulation - GP8.

  • BS 6004:2012

    Table Number:
    Table 3

    Schedule:
    040/001/334

    Approved Range:
    1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 4sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. 1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat twin to flat 3-core inclusive. Class 1 conductor. Sheath - Type 6. Insulation - TI1.

  • BS 6004:2012

    Table Number:
    Table 4

    Schedule:
    040/001/335

    Approved Range:
    1sqmm to 1.5sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat twin to flat 3-core inclusive. Class 1 conductor. 4sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat twin to flat 3-core inclusive. Class 2 conductor. Sheath - Type 6. Insulation - TI1.

  • BS 6004:2012

    Table Number:
    Table 5

    Schedule:
    040/001/336

    Approved Range:
    1.5sqmm nominal cross-sectional area of conductor. Single-core. Class 2 conductor. 1.5sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat twin. Class 2 conductor. Sheath - Type 6. Insulation - TI1.

  • BS 7211:2012

    Table Number:
    Table 5

    Schedule:
    040/001/337

    Approved Range:
    1sqmm to 1.5sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat twin to flat 3-core inclusive. Class 1 conductor. 4sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat twin to flat 3-core inclusive. Class 2 conductor. Sheath - LTS2. Insulation - GP8.

  • BS EN 50525-2-11:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    040/001/338

    Approved Range:
    0.5sqmm to 0.75sqmm nominal cross-sectional area of conductors inclusive. 2-core to 4-core inclusive. Class 5 conductor. Circular cables. 0.5sqmm to 0.75sqmm nominal cross-sectional area of conductors inclusive. 2-core. Class 5 conductor. Flat cables. Sheath - TM2. Insulation - TI2.

  • BS EN 50525-2-11:2011

    Table Number:
    Clause 4.2 Table B.2

    Schedule:
    040/001/339

    Approved Range:
    0.75sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 2-core to 5-core inclusive. Class 5 conductor. Circular cables. 0.75sqmm to 1.5sqmm nominal cross-sectional area of conductors inclusive. 2-core. Class 5 conductor. Flat cables. Sheath - TM2. Insulation - TI2.

  • BS EN 50525-2-11:2011

    Table Number:
    Clause 4.2 Table B.2

    Schedule:
    040/001/340

    Approved Range:
    1.25sqmm nominal cross-sectional area of conductor. 2-core to 3-core inclusive. Class 5 conductor. Circular cables. 1.25sqmm nominal cross-sectional area of conductor. 2-core. Class 5 conductor. Flat cables. Sheath - TM2. Insulation - TI2.

  • BS EN 50525-2-11:2011

    Table Number:
    Clause 5.2 Table B.2

    Schedule:
    040/001/341

    Approved Range:
    0.75sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 2-core to 5-core inclusive. Class 5 conductor. Circular cables. 0.75sqmm to 1.5sqmm nominal cross-sectional area of conductors inclusive. 2-core. Class 5 conductor. Flat cables. Sheath - TM3. Insulation - TI3.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    040/001/342

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.5sqmm to 240sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - TI1.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    040/001/343

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.5sqmm to 240sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - TI1.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.2 Table B.2

    Schedule:
    040/001/344

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - TI1.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.2 Table B.2

    Schedule:
    040/001/345

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - TI1.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.3 Table B.3

    Schedule:
    040/001/346

    Approved Range:
    0.5sqmm to 1sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 & 2 conductor. Insulation - TI1.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.3 Table B.3

    Schedule:
    040/001/347

    Approved Range:
    0.5sqmm to 1sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 & 2 conductor. Insulation - TI1.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.4 Table B.4

    Schedule:
    040/001/348

    Approved Range:
    0.5sqmm to 1sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - TI1.

  • BS EN 50525-2-31:2011

    Table Number:
    Clause 4.4 Table B.4

    Schedule:
    040/001/349

    Approved Range:
    0.5sqmm to 1sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 5 conductor. Insulation - TI1.

  • BS 7629-1:2015

    Table Number:
    Table 2

    Schedule:
    040/001/352

    Approved Range:
    1.0sqmm nominal cross-sectional area of conductor. 2-core. 1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 2-core to 4-core inclusive. STANDARD 60. Additionally tested to BS 6387 Categories C, W & Z. Sheath - LTS3. Insulation - EI2.

  • BS 8436:2011

    Table Number:
    Table 1

    Schedule:
    040/001/353

    Approved Range:
    1sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 2-core to 4-core inclusive. Sheath - LTS3. Insulation - GP8.

  • BS 7211:2012

    Table Number:
    Table 3

    Schedule:
    040/001/354

    Approved Range:
    1.0sqmm to 6sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.0sqmm to 35sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Sheath - LTS4. Insulation - GP8.

  • BS EN 50525-3-41:2011

    Table Number:
    Clause 4.1 Table B.1

    Schedule:
    040/001/355

    Approved Range:
    1.5sqmm to 10sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 1 conductor. 1.5sqmm to 185sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - EI5.

  • BS 7629-1:2015

    Table Number:
    Table 2

    Schedule:
    040/001/356

    Approved Range:
    1.0sqmm nominal cross-sectional area of conductor. 2-core. 1.5sqmm to 4sqmm nominal cross-sectional area of conductors inclusive. 2-core to 4-core inclusive. STANDARD 60. Additionally tested to BS 6387 Categories C, W & Z Sheath - LTS3. Insulation - EI2.

  • I.S. 273:1988 Incorporating Amendment No.1:1993 and Amendment No.2:2003

    Table Number:
    Table 37

    Schedule:
    040/001/357

    Approved Range:
    1.0sqmm to 6sqmm nominal cross-sectional area of conductors inclusive. 2-core to 4-core inclusive. Sheath - LTS3. Insulation - GP8.

  • BS 8592:2016

    Table Number:
    Table 2

    Schedule:
    040/001/358

    Approved Range:
    1.5sqmm to 70sqmm nominal cross-sectional area of conductors inclusive. Single-core. Class 2 conductor. Insulation - EI5. Additionally tested to BS 6387:2013 Categories C, W & Z.

  • I.S. 201-4:2013

    Table Number:
    Table 1 -

    Schedule:
    040/001/359

    Approved Range:
    1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat twin with earth. Class 1 conductor. 1sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat twin with earth. Class 2 conductor. Sheath - Type 6. Insulation - TI1.

  • I.S. 201-4:2013

    Table Number:
    Table 6 -

    Schedule:
    040/001/360

    Approved Range:
    1sqmm to 2.5sqmm nominal cross-sectional area of conductors inclusive. Flat three core plus insulated earth. Class 1 conductor. 1sqmm to 16sqmm nominal cross-sectional area of conductors inclusive. Flat three core plus insulated earth. Class 2 conductor. Sheath - Type 6. Insulation - TI1.

Quality (ISO 9001)

  • CS1-029

    Scope:
    The design, manufacture and supply of the following cable types / products: Flexible Cords & Cables. Power Cables rated up to 1kV, Armoured & Unarmoured. PVC Compounds for use in Electric Cables. Including cables for installations that require safety in the event of a fire.

BASEC PCR

  • PCR-029

    Scope:
    The design, manufacture and supply of the following cable types/products: Flexible Cords and Cables. Power Cables rated up to 1kV, Armoured & Unarmoured. PVC Compounds for use in Electric Cables. Including cables for installations that require safety in the event of a fire.

CPR